Documentation fournisseur
11
7.1.3 FWx
Function Wire Break Monitoring (only F���-xN)
Relay characteristics for wire fault or short circuit, i�e� input frequency = 0
Frequency > SPx
FOx = 1 or 4
FOx = 2 or 3
Frequency < SPx
FOx = 1 or 4
FOx = 2 or 3
Frequency in the range
FOx = 5
FOx = 6
In case of fault the preset analogue initial value AO3 is available at the analogue output�
Values
Default value
7.1.4 NC1
Number of Cams (input 1)
Number of cams detected per revolution� On the basis of this value the monitor calculates
the rotational speed (measured frequency ÷ NC1 = displayed speed in RPM)�
For frequency measurements NC1 = 1 should remain set�
Values
Default value
7.1.5 DIM
Dimension (display format)
Indication in Hz or RPM (revolutions per minute)�
When a new unit is selected, the monitor converts all existing values into the new unit!
Values
Default value
16
252
Notice de montage et d'exploitation – Entraînements pour élévateurs à godets – Série X..e
FWx = inactive (0)
relay energised
relay de-energised
FWx = inactive (0)
relay energised
relay de-energised
FWx = inactive (0)
relay deenergised
relay energised
0 = inactive
1 = active
0
1���999
1
0 = RPM
1 = Hz
0 = RPM
FWx = active (1)
relay de-energised
relay remains de-energised
FWx = active (1)
relay de-energised
relay remains de-energised
FWx = active (1)
relay remains de-energised
relay deenergised