11
DD2503
Evaluation unit for speed monitoring
MONITOR/FR-1 /110-240VAC/DC
Operating conditions
Ambient temperature
Storage temperature
Max. relative air humidity
Protection
Protection rating terminals
Tests / approvals
EMC
MTTF
Mechanical data
Weight
Housing
Dimensions
Materials
Displays / operating elements
Display
Remarks
Remarks
Electrical connection
dual-chamber terminals: 2 x ...2.5 mm²; AWG 14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
236
Notice de montage et d'exploitation – Entraînements pour élévateurs à godets – Série X..e
[°C]
[°C]
[%]
EN 61010
EMV 89/336/EWG
EN 61000-6-2
EN 61000-6-4
[years]
[g]
[mm]
switching status
DC supply voltage (L-)
DC supply voltage (L+)
current supply transistor outputs (L+)
sensor signal pnp
DC Sensor supply (L+)
DC Sensor supply (L-)
AC supply voltage (L)
AC supply voltage (N)
not used
sensor signal npn
not used
not used
relay 1 common
relay 1 normally open
relay 1 normally closed
transistor output 1 pnp
reset 1 pnp
reset 2 pnp
relay 2 common
relay 2 normally open
relay 2 normally closed
analogue output (+)
analogue output (-)
transistor output 2 pnp
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — DD2503-00 — 13.04.2023 —
-40...60
-40...85
80; (40 °C: 50 %)
IP 50
IP 20
2011
2005
2007
152
381.5
housing for DIN rail mounting
78 x 45 x 124.7
plastics
OLED display, 128 x 64 pixels luminous
LED, green
The unit complies with overvoltage category II; pollution degree 2