Faults
Smell of gas.
The pilot light goes out.
The fl ame is yellow.
Burner control knob is stiff .
The heating elements do not
come on
The appliance does not
heat up
to the set temperature
26
FAULT
TROUBLESHOOTING
For any need, please contact Angelo Po's
agents or headquarters, which can be
found in the contacts section of the website
www.angelopo.com.
Causes
Occasional leak because
fl ame has gone out.
The thermocouple has not
warmed up enough.
Burner dirty.
Gas control valve
malfunction.
Electrical connection not
made correctly.
Safety thermostat tripped.
Switch faulty.
Thermostat faulty.
NOTE:
Remedies
Turn off the gas supply tap and
ventilate the room.
Make more attempts to light the
fl ame.
Clean the burner.
NOTE: Contact the after-
sales service.
Check the connection of the
electrical wires
NOTE: Contact the after-
sales service.
Carry out the appliance reset.
NOTE: Contact the after-
sales service.
Replace the switch
NOTE: Contact the after-
sales service.
Replace the thermostat
NOTE: Contact the after-
sales service.
3320060_ut_GB_rev.4