ENGLISH
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
)
Pull off the knob (A).
)
Undo the screws (C) and remove the control
)
panel (B).
Undo the screws (D) and extract the cap (E).
)
Pull off the cone (F).
)
Clean the cone (F) and its seat.
)
Coat the cone with grease (F), fi t it in its seat
)
and turn it a few times.
Pull off the cone (F) to remove the excess
)
grease.
Replace the cone (F) and the cap (E).
)
Replace the control panel (B) and the knob
)
(A) on completion of the operation.
16
GREASING THE GAS TAP
GAS N32 by KLÜBER LUBRICATION ITALIA
S.A.S.
C
A
C
B
NOTE: We recommend gas STABURA-
3320060_inst_GB_rev.4
ADJUSTMENTS
E
F
D