ENGLISH
Check that the hob burners are igniting cor-
)
rectly and their combustion.
Check the gas pressure and fl ow-rate at mini-
)
mum and maximum settings and adjust if
necessary (see page 7).
Check that the safety device is operating cor-
)
rectly.
Check that there are no gas leaks.
)
INSTRUCTIONS AND WARNINGS FOR ADJUSTMENTS
WARNING: Before making any type
of adjustment, activate all the safety de-
vices provided and decide whether staff at
work and those in the vicinity should be in-
formed.
In particular, turn off the gas supply tap, cut
off the electricity supply using the master
switch and prevent access to all devices that
might cause unexpected health and safety
hazards if turned on.
ADJUSTING GAS CONTROL VALVE MINIMUM SETTING TOP BURNERS
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
)
Pull off the knob (A).
)
Undo the screws (C) and remove the control
)
panel (B).
Remove the injector (D) and replace it with
)
the one suitable for the type of gas in use
(see table at back of manual).
Fully screw the injector.
)
After making the setting, seal the screw with
)
paint.
Replace the control panel (B) and the knob
)
(A) on completion of the operation.
14
After testing, if necessary instruct the user in all
the skills necessary for putting the appliance
into operation in conditions of safety, in ac-
cordance with legal requirements.
ADJUSTMENTS
quired if the type of gas to be connected is
diff erent from that used for testing, after
changing the gas supply (see page 13).
ried out by authorised, qualifi ed staff , in ac-
cordance with the relevant legal require-
ments.
Check that the nameplates specify the cor-
)
rect gas for the country of use.
NOTE: These adjustments are only re-
WARNING: Adjustments must be car-
C
A
C
B
ADJUSTMENTS
D
3320060_inst_GB_rev.4