ENGLISH
REPLACING THE TOP BURNER NOZZLE Ø 110 7 KW
To carry out this operation, proceed as follows.
Turn off the gas supply
)
tap.
Remove the grid (A).
)
Extract the burner (B).
)
Unscrew the nozzle (C)
)
and replace it with the
one suitable for the type
of gas in use (see table at
back of manual).
Replace the burner and
)
the grid.
REPLACING THE TOP BURNER NOZZLE Ø 130 10 KW
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
)
Pull off the knob (A).
)
Undo the screws (C) and remove the control
)
panel (B).
Unscrew the nozzle (D) and replace it with
)
the one suitable for the type of gas in use
(see table at back of manual).
Replace the control panel (B) and the knob
)
(A) on completion of the operation.
REPLACING THE TOP BURNER PILOT LIGHT NOZZLE
To carry out this operation, proceed as follows.
)
Turn off the gas supply tap.
Pull off the knob (A).
)
Undo the screws (C) and remove the control
)
panel (B).
Unscrew the union (D).
)
Remove the nozzle (E) and replace it with the
)
one suitable for the type of gas in use (see ta-
ble at back of manual).
Retighten the union (D).
)
Replace the control panel (B) and the knob
)
(A) on completion of the operation.
18
A
B
C
A
C
B
C
A
C
B
3320060_inst_GB_rev.4
REPLACING PARTS
8
C
D
8
D
E
10