Télécharger Imprimer la page

Pratissoli KSR Serie Manuel D'utilisation Et D'entretien page 57

Masquer les pouces Voir aussi pour KSR Serie:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 62
18.2
KSGR pump
18.2.1
Operating instructions
The KSGR series pump has been designed to
operate in environments with atmospheres that are
not potentially explosive and for using water rich
in particulate, therefore it is considered ideal for
systems with fluid recirculation.
The durability of the piston seals is directly in
relation to the percentage of the presence of solids
in the fluid as regards both their size and their
density.
For a long seal life we recommend a particulate
grain size of no more than 200 micron and 20% max.
in volume.
For more information and a general system layout,
see par. 9.7.
18.2.5
Technical characteristics
Model
Version without
KSGR 36
reduction unit
Version without
reduction unit
KSGR 40
Version with
reduction unit
18.2.2
The maximum permissible water temperature is
40°C. However, the pump can be used with water up
to a temperature of 60°C, but only for short periods.
In this case, it is best to consult the Technical Office
or Customer Service Department.
18.2.3
The rated specifications stated in our catalog are the
maximum that can be obtained by the pump. Independently
of the power used, the maximum pressure and rpm indicated
on the specification label can never be exceeded unless
prior formal authorization is given by our Technical Office or
Customer Service Department.
18.2.4
The minimum permissible speed of the crankshaft for these
types of pumps is 100 rpm; any rpm other than as shown in
the performance table (see par. 18.2.5) must be expressly
and formally authorized by the Technical Office or Customer
Service Department.
Flow rate
Rpm
l/min
Gpm
1380
210
55.48
1200
1500
226
60
1800
2200
57
Water temperature
Maximum pressure and flow rate
Minimum operating speed
Pressure
bar
psi
160
2320
138
2000
Power
kW
HP
63.9
87
55
75

Publicité

loading

Ce manuel est également adapté pour:

Ks serieKsgr serieKs 28Ks 32Ks 36Ks 40