• Power cables must be the ordinary polyvinyl chloride sheathed type, designation 60227 IEC53 (RVV), and comply with standards
GB/T 5023.5-2008/IEC 60227-5:2003.
• The three power supply cable conductors must have a nominal cross-section of no less than 0.75 mm
connected to the earthing terminal of the appliance.
• To connect the remote HMI/Modbus master unit to the machine, use cables with a cross-section of between 0.35 mm
Maximum length 12 m. Given that the display connection cable should be kept separate or away from the power cables, the use
of shielded cables is advisable if electromagnetic interference problems are encountered from other devices installed in the room
(causing malfunctioning of the display).
• Use cables with a minimum cross-section of 0.5 mm
7.1
Remote control panel installation and connection
The control panel is wall-mountable (fig. 11). Screws and dowels are not included in the supply.