1640 0284 62
Applicable aux schémas des circuits de puissance du QAC 1350-1500 TwinPower
Legend
Color codes
0 = black
5 = green
1 = brown
6 = blue
2 = red
7 = purple
3 = orange 8 = grey
4 = yellow
9 = white
54 = green/yellow
Wire sections
aa = 0.5 mm²
a = 1 mm²
b = 1,5 mm²
bx = 1,5 mm² NSGAFOÜ
c = 2,5 mm²
cx = 2,5 mm² NSGAFOÜ
d = 4 mm²
e = 6 mm²
f = 10mm²
fx = 10mm² NSGAFOÜ
h = 25 mm²
jx=50 mm² NSGAFOÜ
l = 95 mm²
lx = 95 mm² NSGAFOÜ
x = 2 x 150 mm² NSGAFOÜ
z = 185 mm² NSGAFOÜ
Main breaker settings
Voltage
Q1-Q2
Ir
380V-50Hz
In = 1250A
0.9 x In
12s
400V-50Hz In = 1250A
0.8 x In
12s 4 x Ir 100ms 4 x In
690V-50Hz In = 1250A
0.5 x In
12s 4 x Ir 100ms 4 x In
380V-60Hz In = 1250A
0.9 x In
12s 4 x Ir 100ms 4 x In
440V-60Hz In = 1250A
0.8 x In
12s 4 x Ir 100ms 4 x In
480V-60Hz In = 1250A
0.7 x In
12s 4 x Ir 100ms 4 x In
690V-60Hz In = 1250A
0.4 x In
12s 4 x Ir 100ms 4 x In
Components
TAG
Desc. 1
G1
ALTERNATOR
G2
ALTERNATOR
T1
CURRENT TRANSFORMER
T2
CURRENT TRANSFORMER
T3
CURRENT TRANSFORMER
T4
CURRENT TRANSFORMER
T5
CURRENT TRANSFORMER
T6
CURRENT TRANSFORMER
T7
TOROID
T8
TOROID
Q1
MAIN CIRCUIT BREAKER
Q2
MAIN CIRCUIT BREAKER
Q3
MAIN CIRCUIT BREAKER UL
Q4
MAIN CIRCUIT BREAKER UL
SB4
EMERGENCY STOP
F7
FUSE
F8
FUSE
F9
FUSE
N3
NEUTRAL BAR
F10
FUSE
F11
FUSE
F12
FUSE
N4
NEUTRAL BAR
F19
FUSE
F20
FUSE
F21
FUSE
N7
NEUTRAL BAR
F22
FUSE
F23
FUSE
F24
FUSE
N8
NEUTRAL BAR
F28
FUSE
F29
FUSE
F30
FUSE
N9
NEUTRAL BAR
F31
FUSE
F32
FUSE
F33
FUSE
N10
NEUTRAL BAR
T11
CURRENT TRANSFORMER
T12
CURRENT TRANSFORMER
T13
CURRENT TRANSFORMER
T21
CURRENT TRANSFORMER
T22
CURRENT TRANSFORMER
T23
CURRENT TRANSFORMER
tr
Isd
tsd
Ii
N
T31
CURRENT TRANSFORMER
4 x Ir
100ms
4 x In
4P4D
T32
CURRENT TRANSFORMER
T33
CURRENT TRANSFORMER
4P4D
T41
CURRENT TRANSFORMER
4P4D
T42
CURRENT TRANSFORMER
T43
CURRENT TRANSFORMER
4P4D
T51
CURRENT TRANSFORMER
4P4D
T52
CURRENT TRANSFORMER
4P4D
T53
CURRENT TRANSFORMER
T61
CURRENT TRANSFORMER
4P4D
T62
CURRENT TRANSFORMER
T63
CURRENT TRANSFORMER
V1
ANALYZER
V2
ANALYZER
V3
ANALYZER
V4
ANALYZER
V5
ANALYZER
V6
ANALYZER
K31
RELAY ANALYZER
K32
RELAY ANALYZER
Conectors
Desc. 2
Generator
Pg.
Location
X3-X4
1
2-6
1A
PIN
2
2-6
6A
1
L1
1
2-6
2B
2
L2
1
2-6
2B
3
L3
1
2-6
2B
4
L1
2
2-6
6B
5
L2
2
2-6
6B
6
L3
2
2-6
7B
7
1
2-6
1D
8
2
2-6
6D
9
1
2
1D
10
2
2
6D
11
1
6
1D
12
2
6
6D
13
1-2
2-6
5D-10D
14
250mA
1
2-6
3C
15
250mA
1
2-6
3C
16
250mA
1
2-6
3C
17
1
2-6
3C
18
250mA
1
2-6
3F
19
250mA
1
2-6
3F
20
250mA
1
2-6
3F
21
1
2-6
3F
22
250mA
2
2-6
7C
23
250mA
2
2-6
7C
24
250mA
2
2-6
7C
25
2
2-6
7C
26
250mA
2
2-6
7F
27
250mA
2
2-6
7F
28
250mA
2
2-6
7F
29
2
2-6
7F
25A
1
2-6
3B
X6
25A
1
2-6
3B
PIN
25A
1
2-6
3B
1a
2
2-6
3B
2a
25A
2
2-6
7B
1b
25A
2
2-6
7B
2b
25A
2
2-6
7B
2
2-6
7B
X8
PIN
L1
1
4-7
1F
L2
1
4-7
1F
1
L3
1
4-7
1F
2
L1
1
4-7
5F
X14
L2
1
4-7
5F
L3
1
4-7
5F
PIN
1
L1
1
4
8F
L2
1
4
8F
2
3
L3
1
4
8F
L1
2
5-8
1F
4
L2
2
5-8
1F
X43-X46
L3
2
5-8
1F
PIN
L1
2
5-8
5F
L2
2
5-8
5F
1
2
L3
2
5-8
5F
3
L1
2
5
8F
4
L2
2
5
8F
PE
L3
2
5
8F
1
4-7
3D
1
4-7
6D
1
4
9D
2
5-8
3D
2
5-8
6D
2
5
9D
2NC
1
4-7
10B
2NC
2
5-8
10B
- 112 -
POWER CUBICLE TO CONTROL CUBICLE
Pg.
Desc. 1
Connector
Location
Open Main CB
X3-X4
2
4F-9F
Close Main CB
X3-X4
2
4F-9F
Main CB opened
X3-X4
2
5F-9F
Main CB closed
X3-X4
2
4F-9F
Negative
X3-X4
2
3F-8F
Positive
X3-X4
2
3F-8F
Com. CT's
X3-X4
2
3B-8B
CT L1
X3-X4
2
3B-8B
CT L2
X3-X4
2
3B-8B
CT L3
X3-X4
2
3B-8B
U1
X3-X4
2
3C-8C
U2
X3-X4
2
3C-8C
U3
X3-X4
2
3C-8C
N1
X3-X4
2
3C-8C
L1
X3-X4
2
3F-8F
L2
X3-X4
2
3F-8F
L3
X3-X4
2
3F-8F
N
X3-X4
2
3F-8F
UV coil (+)
X3-X4
2
5F-9F
T1 (toroid)
X3-X4
2
1D-5D
T2 (toroid)
X3-X4
2
1D-5D
Emergency stop
X3-X4
2
5F-10F
Emergency stop
X3-X4
2
5F-10F
Alarm light
X4
2
8F
Alarm horn
X4
2
8F
Internal light (+)
X4
2
10F
Internal light (-)
X4
2
10F
Internal light pushbutton
X4
2
10F
Internal light pushbutton
X4
2
10F
POWER CUBICLE TO ALARM BOX
Pg.
Desc. 1
Connector
Celda
Alarm light
X6
2
7F
Negative
X6
2
7F
Alarm horn
X6
2
7F
Negative
X6
2
7F
POWER CUBICLE TO INTERNAL LIGHT
Desc. 1
Connector
Pg.
Celda
Positive
X8
2
10F
Negative
X8
2
10F
EMERGENCY STOP SB4 & SB5
Pg.
Desc. 1
Connector
Celda
Switch
X14
2
5E
Positive
X14
2
5E
Switch
X14
2
10E
Positive
X14
2
10E
SUPPLY ALT1 - ALT2
Desc. 1
Connector
Celda
U
X43-X46
3B-8B
V
X43-X46
3B-8B
W
X43-X46
3B-8B
N
X43-X46
3B-8B
PE
X43-X46
3B-8B