part nr 425083. Earth ground terminal.
part nr 446237. Earth ground terminal.
1.2.c. ELECTRICAL AND PNEUMATIC
CONNECTIONS
The dimensions of the electric hook-up used
must be suitably sized in relation to:
• the electric power absorbed by the ma-
chine, indicated on its data plate (Fig. 1);
• the distance between the machine and the
power supply hook-up point, so that voltage
drops under full load do not exceed 4% (10%
during start-up) compared with the rated voltage
speciied on the data plate.
- The operator must:
• it a power plug on the power supply lead in com-
pliance with the relevant safety standards;
• connect the machine to its own electrical connec-
tion - A, Fig. 2 - and it a differential safety circuit-
breaker with 30 mA residual current;
• it fuses to protect the power supply line, rated
as indicated on the general wiring diagram in this
manual;
• connect the machine to an industrial socket; the
machine must not be connected to domestic sockets.