Terminal assignment
NOTICE!
Only skilled personnel are authorised to carry out all changes to the terminal
assignment. Contact
need assistance.
Fig. 12: Terminal assignment 'EcoPro'
L1 Mains phase (live conductor)
N
Neutral (earth)
Permissible external cable
AD Ø = 5.1-5.7 mm. LIYY 4x0.5; LIYY 5x0.34; LYCY 2x0.34
Permissible cables: Oilflex 4x0.5
IP65 is applicable only when the specified cable is being used.
Mains power supply
CAUTION!
– Work on the mains connection may only be carried out by skilled personnel
who are duly trained and authorised.
– Within the jurisdiction of the EU, the electrical connection should be
performed in line with the latest valid CE regulations.
– In addition, observe the appropriate national regulations and local utility
company regulations.
– The mains voltage value must match the value specified on the nameplate.
The mains cable is pre-assembled at the factory.
Should the mains cable need to be replaced due to local conditions, it is essential
that all the descriptions and instructions given below are observed.
L1 = mains phase (live conductor)
Colour: Brown
N = neutral conductor
Colour: Blue
Ä 'Manufacturer' on page 11 if you have any queries or
8
Enable input: GND
9
Enable input: enable signal
Ø for connecting the inputs/outputs:
41
Assembly and connection
MAN046879 Rev. 12-01.2024