WARNING!
Proper use particularly includes the following points:
– Only liquid, validated chemicals may be metered.
– Depending on the material used, the metering system is designed for acidic
and alkaline products.
– The EcoPro has been developed and built for industrial and commercial
use. The unit is not intended for private use.
– The following data and settings must comply with the
Ä Chapter 13 'Technical data' on page 81 :
– Permissible ambient temperature, media temperature
– back pressure
– Metering rates
– Operating voltage
Any use which extends beyond or differs from the intended use is
considered improper use.
Danger in case of misuse
WARNING!
Improper use can lead to dangerous situations:
– Do not use metering media other than the specified product.
– Do not change the metering specifications for the product.
– Never use in potentially explosive areas.
– As with any device that includes microprocessors, avoid switching the
power supply on and off on a frequent basis. Use the metering release to
start and stop the pump and be aware of the higher start-up current during
start-up.
– The voltage must not be interrupted during start-up.
– Wear the prescribed personal protective equipment (PPE).
Reasonably foreseeable incorrect use
To maintain proper function, pay attention to the particular handling instructions.
Observance of these instructions can avoid any foreseeable incorrect use, according to
the risk analysis conducted by the manufacturer.
n
Incorrect use of design variants
(e.g. incorrect sealing materials, incorrect pump head materials).
n
Operating the unit using incorrect voltage supplies.
n
Excessive back-pressures.
n
Incompatible accessory parts.
n
Incorrect dosing lines.
n
Line cross-sections that are too small.
n
Incorrect ambient temperatures or media temperatures.
n
Excessive viscosities.
Operation in potentially explosive atmospheres.
n
n
Use of unsuitable dosing media.