Baker SF 950+ / 550
ALARMS
Code
OP
The door is open (or the door switch is closed in another manner).
A1
Door alarm "dA" was activated.
A2
Local alarm, maximum value was activated (LHL)
Room temperature sensor is defective. The sensor must be replaced by the service department. The
F1
cabinet will still approximately maintain the preset temperature with the use of an emergency program.
If "F2" is shown, the evaporator sensor is defective, or there is extreme icing up of the evaporator.
Initially, the unit must be completely defrosted one single time (disconnected, after which the cabinet
must stand with an open door for 24 hours), Important - condensation container under the unit may run
F2
over in connection with this!). If the fault subsequently continues to be displayed, then the service
department must replace the sensor a quickly as possible. The pre-set temperature will continue to be
maintained, and the defrosting phase will occur gradually without temperature restrictions.
If "F3" is displayed, there are problems with the condensation sensor. This sensor only protects against
overheating, and it has no influence on the temperature regulation in the cabinet. It ought however to
F3
be replaced as quickly as possible, so the protection against overheating is re-established
Faults in the second condensation sensor in connection with units with two
F4
cooling motors (see fault message "F3").
Fault in the temperature sensor for PCL (hard chill). The sensor must be replaced, contact the service
F5
department. Affects only hard chill
Overheating of condenser or undercooling, filter mats or condenser fins plugged up, fan defective,
ambient temperature too high or low (unit not in operation with ambient temperature of under +16°C)
F7
*does not apply for models with external cooling motors.
DELETING ALARM MESSAGES
The A1 alarm is deleted by pressing the
A1
The A1 alarm is deleted by pressing the button. The temperature in the cabinet must first
A2
be under the desired max. temperature (25 °C default)