Baker SF 950+ / 550
TIME CONTROLLED COOLING (SOFT CHILL)
This program gently cools down to the selected, desired value
(controlled using room sensor). Both compressors perform the
cooling in parallel. The second compressor starts 15 seconds after the first one. The
fan runs at a high RPM figureThe program is started by pressing the button:
Temperature changes with Soft Chill: The program is governed solely by the room sensor. The air
temperature and goods being chilled are thus taken into account. The elapsed time has no effect on
the course of the program. The cooling system works with start/stop cycles with a gradient up to
the preset storage temperature. The process stops as soon as the temperature value reaches 0 °C,
and the controls switch to the storage program.
After pressing the
button, it will be lit continuously.
The
and
buttons will blink. The curve symbol
for Soft Chill will light up. The secondary display shows the
program name "SCL" and the tertiary display the selected
desired temperature value. The
and
buttons
are
used to change the desired value and button
for starting the
program. The primary display will now show the current
temperature in the room, the secondary display the program
name "SCL" and the tertiary display the selected, desired
temperature value. The curve symbol is now continuously
displayed. In addition, the
connected elements will now be continuously lit: both
compressors, both fan symbols for a high fan RPM figure.
When the desired value is attained, an acoustic signal will be
emitted. After the signal, defrosting is commenced (if such is
required based upon the evaporator sensor's temperature). Then it
subsequently switches to the storage program. Hence the desired
value for the storage program must always be set and checked
before starting "SCL"!
15
EN