Baker SF 950+ / 550
DRY COOLING
DRY
Menu Item
DC
DOOR MONITORING
When the door is opened "OP" is shown in the primary display.
An acoustic signal is emitted, and the "A1" message is shown on
the secondary display, if the door at a minimum is open in "Dad",
and "BU" is connected.
The acoustic alarm is deleted by pressing
indicator only or first shuts off once the door has also been closed.
CLEANING THE CONDENSER FILTER
Reminder of cleaning condenser air filter:
After 600 compressor running hours the filter must ve cleaned an it is indicated by warning lights:
If the cleaning is not completed within 650 hours, the warnings continue, and an acoustic alarm does sound.
Resetting the filter alarm after cleaning the condenser filter:
After cleaning the air filter, the controller must be reset to remove the alarms. It can only be reset by using a
certain key combination.
Push
button for three times followed by pushing
into green and will disappear after 1 minute.
Dry cooling function may only be selected via the user menu. The user menu is
opened by pressing
now be switched in or out under the dc menu item, saved with
which the menu is exited with
Description
Dry cooling function
the button for approx. 3 seconds. The function can
button.
Settings Range
Activation: "ON
Deactivation: "OFF"
button The alarm
button for three times. FILTER alarm lights turn
EN
button after
Factory Setting
OFF
18