Baker SF 950+ / 550
When the
button is released, an auditory signal
is issued and the value is saved. The display once again
will show the internal temperature within the unit.
Regulation in HCL, PCL, SCL
During storage, the evaporator fans run at low speed. In the programs HCL, PCL,and SCL
compressor 2 is cut in immediately or delyed, and the fans start to run at hign speed.
Aggregates:
Storage
HCL (time
controlled)
PCL (Hardchill)
SCL (Softchill)
Relay Contacts:
Storage
HCL (time
controlled)
PCL (Hardchill)
SCL (Softchill)
Compressor 1
ON / OFF
Temperature
controlled
ON
ON
ON / OFF
Temperature
controlled
K1
ON / OFF
Temperature
controlled
ON
ON
ON / OFF
Temperature
controlled
EN
Evaporator fan
Compressor 2
SF 950plus:0 / 50
OFF
ON
ON
ON / OFF
Temperature
controlled
K2
ON / OFF
Temperature
controlled
ON
ON
ON / OFF
Temperature
controlled
RPM
%
Temperature
controlled
100 %
100 %
50 % / 100 %
Temperature
controlled
K5
OFF
ON
ON
50 % / 100 %
Temperature
controlled
12