Baker SF 950+ / 550
THE USER MENU
The user menu is opened by pressing the
seconds.
Navigate through the menu using the using the "+" and "-" buttons, after which the selected menu item is opened
with the "P" button. The "+" and "-" buttons increase or decrease the value. They are also used to navigate around
in the submenu ("LAL"). The manner of procedure is the same in the submenu. Altered values are saved by
pressing on "P" (receipt acoustic signal!). Exiting menu items or the menu are done by pressing "ON/OFF"
Menu item
DC
LAL
Local Alarm (display)
LHL
LHd
DA
Dad
BU
CAL
Temperature offset (sensor harmonistation)
Temperature offset sensor input A
CA
Temperature offset sensor input A
CE
ALL
DEF
Description
Dry Cooling Function
Upper boundary value for LAL
Delay for LHL
Door Alarm
Delay for door alarm
Acoustic alarm for LAL
(room sensor)
(room sensor)
Relative (escorted) or
absolute (fixed) alarm limits
Number of defrosting cylces for
each 24 hours.
Settings Range
Activation : "ON"
Deactivation: "OFF"
+25 ........ -35 °C
1 .... 120 min / in steps of 5 minutes
0 = OFF
1 = ON
0 ...... 15 min
0 = OFF
1= ON
-5 ...... +5 K /steps of 0.5 K
-5 ...... +5 K /steps of 0.5 K
ESC = Escorted
FAS = Fixed
0 ....... 8
EN
button for approx. 3
Factory Setting
OFF
+ 25 °C
60 min
1
1
1
0.0 K
0.0 K
FAS
4
17