Baker SF 950+ / 550
TIME CONTROLLED COOLING "HCL"
This program is time-controlled only. The air temperature and the
temperature of the contents of the cabinet are not taken into account.
Both compressors perform the cooling in parallel. The second
compressor starts 15 seconds after the first one. When the proper
evaporator temperature is attained, the fan will be running audibly with
a very high RPM figüre.
The program is selected by pressing the button :
When the
button is pressed, it will stay lit continuously,
and the
and
buttons will blink. The symbol
for the clock will light up. The secondary display will show the
program name "HCL" and the tertiary display the selected
duration in minutes. The symbols for a high fan RPM figure
and operation with 2 compressors will be blinking. The
and
buttons are used to change the time, and
button for starting the program.
While the program is running, the time will count down on
the tertiary display. The primary display will show the current
temperature inside the unit. In addition, the connected
elements will now be continuously lit: Both compressors,
both fan symbols for a high fan RPM figure
When the desired value is attained, an acoustic signal is emitted.
After the signal, defrosting is commenced (if such is required
based upon the evaporator sensor's temperature). Then it
subsequently switches to the storage program.
Hence the desired value for the storage program must
always be set and checked before starting "HCL"!