Setup menus
INTERFACE menu
Item
Superimposed
No.
display
202
ID SEL
205
BAUD RATE
206
DATA LENGTH
207
STOP BIT
208
PARITY
270
FLOW CONTROL
271
EDL FORMAT
The underlining indicates the factory setting.
Setting
Superimposed
No.
display
This selects the ID information to be returned to the controller.
0000
OTHER
0: 20 25H (525i mode) is returned.
0001
DVCPRO
1: The DVCPRO's own ID and F0 33H (525i mode) is returned.
<Note>
This operation is not performed in the 625i mode.
0000
1200
This selects the RS-232C (EDL) transfer (baud) rate.
0001
2400
0002
4800
0003
9600
0004
19200
This selects the RS-232C (EDL) data length.
0000
7
0: 7 bits
0001
8
1: 8 bits
This selects the RS-232C (EDL) stop bit.
0000
1
0: 1 bit
0001
2
1: 2 bits
This selects the RS-232C (EDL) parity.
0000
NON
0: Parity bit is not used.
0001
ODD
1: Parity bit is used with odd parity.
0002
EVEN
2: Parity bit is used with even parity.
This selects the RS-232C (EDL) communication flow control.
0000
NONE
0: No flow control using RTS/CTS.
0001
RTSCTS
1: Flow control using RTS/CTS.
This selects the format in which the EDL is to be dumped.
0000
AGA850
0: Format which is common with Panasonic's AG-A850.
0001
CMX340
1: Format which is common with the CMX340 editing system.
35
Description of setting
V
V
T
T
R
R
1
2
[
[
[
[
[
[
[
[