Setup menus
TIME CODE menu
Item
Superimposed
No.
display
500
VITC BLANK
501
VITC POS-1
(525i mode)
(625i mode)
502
VITC POS-2
(525i mode)
(625i mode)
503
TCG REGEN
504
REGEN MODE
The underlining indicates the factory setting.
Setting
Superimposed
No.
display
This selects whether to output the VITC signal at the positions
which have been set by setup menu item No.501 (VITC POS-1)
and No.502 (VITC POS-2).
0000
BLANK
0: The VITC signal is not output.
0001
THRU
1: The VITC signal is output.
0000
10L
This selects the position where the VITC signal is inserted.
<Note>
0006
16L
The same line as the one selected by setup menu item No.502
(VITC POS-2) cannot be set.
0010
20L
0000
7L
0004
11L
0015
22L
0000
10L
This selects the position where the VITC signal is inserted.
<Note>
0008
18L
The same line as the one selected by setup menu item No.501
(VITC POS-1) cannot be set.
0010
20L
0000
7L
0006
13L
0015
22L
This selects the signal to be regenerated when the TCG (time
code generator) is in the regeneration mode.
0000
TC&UB
0: Both the time code and user's bit are regenerated.
0001
TC
1: Only the time code is regenerated.
0002
UB
2: Only the user's bit is regenerated.
This selects when the time code is to be regenerated during
automatic editing (assemble editing or insert editing).
0000
AS&IN
0: The time code is regenerated in assemble editing or insert
editing.
0001
ASSEM
1: The time code is regenerated in assemble editing.
0002
INSRT
2: The time code is regenerated in insert editing.
0003
SW
3: The time code regeneration accords with the REGEN/PRESET
switch position.
41
Description of setting
V
V
T
T
R
R
1
2
[
[
[
[
[
[
[
[
[