4

GENERAL INFORMATION

4.1
Contact addresses
Germany
Bürkert Fluid Control Systems
Sales Center
Christian-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. + 49 (0) 7940 - 10 91 111
Fax + 49 (0) 7940 - 10 91 448
E-mail: info@burkert.com
International
Contact addresses are found on the final pages of the printed
operating manual. You can also find information on the Internet
under:
www.burkert.com
4.2
Warranty
The warranty is only valid if the device is used as authorized in
accordance with the specified application conditions.
4.3
Conformity
The device conforms to the EU Directives as per the EU Decla-
ration of Conformity (if applicable).
4.4
Standards
The applied standards, which are used to demonstrate conformity
with the EU Directives, are listed in the EU type examination cer-
tificate and/or the EU Declaration of Conformity (if applicable).
6
english
Type 2006
General Information
5

TECHNICAL DATA

5.1
General technical data
Control functions (CF)
Control function A Closed by spring force in rest position
Control function B Opened by spring force in rest position
Control function I Actuating function via reciprocal
pressurization
Materials and Connections
see datasheet
Media
Control media
Neutral gases, air
Flow media
Water, alcohols, oils, fuels, hydraulic liquid,
saline solutions, lyes, organic solvents,
steam
Installation position Any position, preferably with actuator face up
5.2
Type label (example)
Orifice
Control function
Type
2006 A 50,0 PTFE VA
G1 1/2
Pilot 6–10bar
Pmed 1–2 : 9bar
Pmed 2–3/1: 16bar
00287199
Seal material
Body material
Port connection
Pilot pressure
Max. medium
pressure
W34ME