Summer/Winter Time; Display Settings - Fronius Primo 3.0-1 Instructions De Service

Masquer les pouces Voir aussi pour Primo 3.0-1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Summer/winter time

Activate/deactivate automatic changeover between summer and winter time
IMPORTANT! Only use the automatic summer/winter time changeover function if the
Fronius Solar Net ring does not include any LAN- or WLAN-compatible system compo-
nents (e.g. Fronius Datalogger Web, Fronius Datamanager or Fronius Hybridmanager).
Setting range
Factory setting
IMPORTANT! The time and date must be set accurately in order for the day and year val-
ues and for the day characteristic to be displayed correctly.

Display settings

Setting range
Language
Set language for display
Setting range
Night mode
Night mode controls Fronius DATCOM and inverter display operation during the night or
when the DC voltage is insufficient
Setting range
Factory setting
Contrast
Set the contrast on the inverter display
Setting range
Factory setting
32
on / off
on
Language / Night mode / Contrast / Illumination
English, German, French, Spanish, Italian, Dutch, Czech, Slo-
vakian, Hungarian, Polish, Turkish, Portuguese, Romanian
AUTO / ON / OFF
OFF
AUTO:
Fronius DATCOM mode is always in effect as long as there is a Fronius Da-
tamanager connected in an active and uninterrupted Fronius Solar Net.
The inverter display remains dark during the night, but can be activated by
pressing any function button.
ON:
Fronius DATCOM mode is always in effect. The inverter supplies 12 V of DC
voltage continuously to power the Fronius Solar Net. The display is always
active.
IMPORTANT! If Fronius DATCOM night mode is set to ON or AUTO when
there are Fronius Solar Net components connected, the inverter's current
consumption during the night will increase to around 7 W.
OFF:
Fronius DATCOM will not run at night, the inverter therefore does not require
any power during the night to supply the Fronius Solar Net with energy.
The inverter display is switched off during the night and the Fronius Datama-
nager is not available. To nevertheless activate the Fronius Datamanager,
switch the inverter off and on again at the mains and press any function but-
ton on the inverter display within 90 seconds.
0 - 10
5