System monitoring
General
The inverter is fitted with the WLAN-enabled system monitoring Fronius Datamanager 2.0
as standard.
The following functions are included with the system monitoring:
-
-
-
-
-
-
-
-
-
Further information on Fronius Datamanager 2.0 can be found online in the Fronius Data-
manager 2.0 Operating Instructions.
Fronius Dataman-
The Night Mode parameter under "Display Settings" in the Setup menu is preset to OFF in
ager during the
the factory.
night or when the
For this reason the Fronius Datamanager cannot be accessed during the night or when the
available DC volt-
available DC voltage is insufficient.
age is insufficient
To nevertheless activate the Fronius Datamanager, switch the inverter off and on again at
the mains and press any function button on the inverter display within 90 seconds.
See also the chapters on "Menu items in the Setup menu", "Display settings" (Night Mode).
Using for the first
Setting up the Fronius Datamanager 2.0 for the first time is made considerably easier with
time
the Fronius Solar.web app. The Fronius Solar.web app is available in the respective app
stores.
When starting Fronius Datamanager 2.0 for the first time,
-
-
IMPORTANT! In order to establish a connection to Fronius Datamanager 2.0, "Obtain IP
address automatically (DCHP)" must be activated on the end device in question (e.g. lap-
top, tablet, etc.).
14
Dedicated web page displaying current data and a wide range of settings
Ability to connect to Fronius Solar.web using WLAN or LAN
Automatic sending of service messages by SMS or e-mail in the event of a fault
Option of controlling the inverter by specifying power limit values, minimum or maxi-
mum running times or target running times
Control of the inverter via Modbus (TCP / RTU)
Ability to assign control priorities
Ability to control the inverter by means of connected meters (Fronius Smart Meter)
Ability to control the inverter via a ripple control signal receiver (e.g. by specifying the
reactive power or effective power)
Dynamic power reduction, taking self-consumption into account
the Fronius Datamanager 2.0 plug-in card must be installed in the inverter,
or
there must be a Fronius Datamanager Box 2.0 in the Fronius Solar Net ring.