Fronius Primo 3.0-1 Instructions De Service page 21

Masquer les pouces Voir aussi pour Primo 3.0-1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Values displayed in the LOG menu item:
(for today, during the current calendar year and since the inverter was started for the first
time)
AC Energy Yield (kWh / MWh)
Energy fed into the grid during the period in question
There may be discrepancies with values displayed on other measuring instruments be-
cause of differences in measuring methods. As far as the billing of the energy fed in is
concerned, the only binding display values are those produced by the calibrated measur-
ing device provided by the electricity supply company.
AC Max. Output Power (W)
Largest amount of power fed into the grid during the period in question
Earnings
Amount of money earned during the period in question (currency can be selected in the
Setup menu)
Like the energy supplied figure, the yield figure may also exhibit discrepancies with other
measured values.
The 'Setup Menu' section explains how to select a currency and charge rate.
The factory setting depends on the respective country setup.
CO2 savings (g / kg)
CO
emissions saved during the period in question
2
The value for CO
savings depends on the power station facilities and corresponds to the
2
CO
emissions that would be released when generating the same amount of energy. The
2
factory setting is 0.53 kg / kWh (source: DGS – Deutsche Gesellschaft für Sonnenenergie
e.V. (German Society for Solar Energy).
AC Max. Voltage L-N (V)
Highest voltage measured between the conductor and neutral conductor during the peri-
od in question
PV Array Max. Voltage (V)
Highest solar module voltage measured during the period in question
Operating Hours
Length of time the inverter has been working (HH:MM).
IMPORTANT! A prerequisite for the correct display of day and year values is that the time
is set correctly.
21

Publicité

Table des Matières
loading

Table des Matières