Page 1
I I s s o o A A i i r r ® ® S S y y s s t t e e m m O O p p e e r r a a t t i i o o n n s s M M a a n n u u a a l l 2941 2941-009-001 Rev AA.0 2021/07...
Page 3
S S y y m m b b o o l l s s Refer to instruction manual/booklet Consult instructions for use General warning Caution Cardiopulmonary resuscitation (CPR) Indicates that this product does not contain toxic and hazardous substances or elements above the maximum concentration of all 6 values defined by the China RoHS legislation.
Page 4
Solids: Protection from touch by fingers and objects greater than 12 mm I I P P 2 2 1 1 Liquids: Protection from the fall of vertical water drops For US Patents see www.stryker.com/patents Keep dry Stacking limit by number...
Page 5
T T a a b b l l e e o o f f C C o o n n t t e e n n t t s s Warning/Caution/Note Definition ........................2 Summary of safety precautions .......................2 Introduction ..............................4 Product description ..........................4 Intended use............................4 Clinical benefits............................4...
Page 6
W W a a r r n n i i n n g g / / C C a a u u t t i i o o n n / / N N o o t t e e D D e e f f i i n n i i t t i i o o n n The words W W A A R R N N I I N N G G , C C A A U U T T I I O O N N , and N N O O T T E E carry special meanings and should be carefully reviewed.
Page 7
• Do not exceed the safe working load of the hospital bed frame when supporting both the patient and the support surface. Excess weight could cause unpredictable safety and performance of this product. • Always make sure that the opposite siderail is raised when you transfer a patient onto the support surface to reduce the risk of patient fall.
Page 8
P P r r o o d d u u c c t t d d e e s s c c r r i i p p t t i i o o n n The Stryker Model 2941, I I s s o o A A i i r r ® system consists of a support surface and pump. The support surface is an air powered support surface that consists of air cells and bladders that run across the surface to support the patient and side bolsters.
Page 9
The I I s s o o A A i i r r pump has a 5 year expected service life under normal use conditions and with appropriate periodic maintenance. D D i i s s p p o o s s a a l l / / r r e e c c y y c c l l e e Always follow the current local recommendations and/or regulations governing environmental protection and the risks associated with recycling or disposing of the equipment at the end of its useful life.
Page 10
N N o o t t e e - - The power cord for this product has a ground conductor that is only used as a functional earth. Stryker reserves the right to change specifications without notice. E E n n v v i i r r o o n n m m e e n n t t a a l l c c o o n n d d i i t t i i o o n n s s...
Page 11
Top cover CPR connector Strap handle Tie down strap D-ring (see Applying linens) Law label location D-ring strap, bottom center AST cable Bottom cover 2941-009-001 Rev AA.0...
Page 12
P P r r o o d d u u c c t t i i l l l l u u s s t t r r a a t t i i o o n n - - p p u u m m p p Graphical user interface Anti-vibration foot Status indicator...
F F i i g g u u r r e e 1 1 – – A A i i r r c c e e l l l l s s A air cell AST air cell Left and right side bolster B air cell Bottom foam assembly Air line, two line manifold...
Page 14
I I c c o o n n N N a a m m e e D D e e s s c c r r i i p p t t i i o o n n Action button, left Allows the operator to select an action on the screen Lock or unlock See Locking or unlocking the screen (page 29)
Page 15
Competent authority of the European Member State where the user and/or patient is established. To view your operations or maintenance manual online, see https://techweb.stryker.com/. Have the serial number (A) of your Stryker product available when calling Stryker Customer Service or Technical Support. Include the serial number in all written communication.
Page 16
S S e e t t u u p p S S e e t t u u p p t t h h e e s s u u p p p p o o r r t t s s u u r r f f a a c c e e Unpack the cartons and check all items.
Page 17
F F i i g g u u r r e e 2 2 – – I I n n s s e e r r t t t t i i e e d d o o w w n n s s t t r r a a p p s s 9.
Page 18
S S e e t t u u p p t t h h e e p p u u m m p p Unpack the cartons and check all items. Make sure that the product operates before you place into service. W W A A R R N N I I N N G G •...
Page 19
b. Setup with InTouch bed (page 17) c. Setup with 3002 S3 bed or 3005 S3 bed (page 18) d. Setup with GoBed II bed (page 19) e. Setup with Spirit Plus bed or Spirit Select bed (page 20) 7. Route the hose on the patient left side of the footboard. N N o o t t e e •...
Page 20
S S e e t t u u p p w w i i t t h h P P r r o o C C u u i i t t y y b b e e d d F F i i g g u u r r e e 6 6 –...
Page 21
S S e e t t u u p p w w i i t t h h I I n n T T o o u u c c h h b b e e d d F F i i g g u u r r e e 8 8 – – R R e e t t a a i i n n i i n n g g s s l l o o t t l l o o c c a a t t i i o o n n s s f f o o r r t t i i e e d d o o w w n n s s t t r r a a p p s s F F i i g g u u r r e e 9 9 –...
Page 22
S S e e t t u u p p w w i i t t h h 3 3 0 0 0 0 2 2 S S 3 3 b b e e d d o o r r 3 3 0 0 0 0 5 5 S S 3 3 b b e e d d F F i i g g u u r r e e 1 1 0 0 –...
Page 23
S S e e t t u u p p w w i i t t h h G G o o B B e e d d I I I I b b e e d d F F i i g g u u r r e e 1 1 2 2 – – R R e e t t a a i i n n i i n n g g s s l l o o t t l l o o c c a a t t i i o o n n s s f f o o r r t t i i e e d d o o w w n n s s t t r r a a p p s s F F i i g g u u r r e e 1 1 3 3 –...
Page 24
S S e e t t u u p p w w i i t t h h S S p p i i r r i i t t P P l l u u s s b b e e d d o o r r S S p p i i r r i i t t S S e e l l e e c c t t b b e e d d F F i i g g u u r r e e 1 1 4 4 –...
Page 25
C C o o n n n n e e c c t t i i n n g g t t h h e e C C P P R R c c o o n n n n e e c c t t o o r r a a n n d d A A S S T T c c a a b b l l e e To connect the CPR connector and AST cable: 1.
Page 26
O O p p e e r r a a t t i i o o n n W W A A R R N N I I N N G G • Always check patient’s skin regularly. Consult a physician if erythema or skin breakdown occurs. Serious injury could result if the patient’s skin condition is left untreated.
Page 27
1. Press and wait for M M a a x x I I n n f f l l a a t t e e to fully inflate. See Starting or canceling Max Inflate (page 23). 2. Position one patient support platform alongside the other patient support platform while minimizing the gap between the two platforms.
Page 28
F F i i g g u u r r e e 2 2 3 3 – – M M a a x x I I n n f f l l a a t t e e N N o o t t e e - - The M M a a x x I I n n f f l l a a t t e e icon blinks until the support surface inflates to the maximum pressure setting. 00:15:00 F F i i g g u u r r e e 2 2 4 4 –...
Page 29
00:15:00 F F i i g g u u r r e e 2 2 6 6 – – C C a a n n c c e e l l M M a a x x I I n n f f l l a a t t e e N N o o t t e e - - No other functions are available until Max Inflate time expires or is canceled.
Page 30
F F i i g g u u r r e e 2 2 9 9 – – S S t t a a t t i i c c m m o o d d e e o o n n N N o o t t e e - - The adjustment arrows illuminate green when you press the A A c c t t i i o o n n button.
Page 31
F F i i g g u u r r e e 3 3 1 1 – – A A L L P P m m o o d d e e o o f f f f N N o o t t e e - - The support surface alternates between zone A and zone B in approximately six minute intervals. 3.
Page 32
S S t t a a r r t t i i n n g g o o r r s s t t o o p p p p i i n n g g t t h h e e A A S S T T m m o o d d e e The AST mode is on by default.
Page 33
F F i i g g u u r r e e 3 3 7 7 – – L L A A L L o o n n L L o o c c k k i i n n g g o o r r u u n n l l o o c c k k i i n n g g t t h h e e s s c c r r e e e e n n You are unable to change modes when the screen is locked.
Page 34
To store the support surface: 1. Start Max Inflate, see Starting or canceling Max Inflate (page 23). 2. Clean and dry the product. 3. Power off the pump. 4. Press the tab in on the CPR connector to disconnect. 5. Remove the CPR connector from the pump. 6.
Page 35
T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g P P r r o o b b l l e e m m S S c c r r e e e e n n C C a a u u s s e e R R e e c c o o m m m m e e n n d d e e d d a a c c t t i i o o n n...
Page 36
P P r r o o b b l l e e m m S S c c r r e e e e n n C C a a u u s s e e R R e e c c o o m m m m e e n n d d e e d d a a c c t t i i o o n n Disconnected air hose Air hose is disconnected 1.
Page 37
P P r r o o d d u u c c t t a a l l a a r r m m s s The product alarms for this product are visual only. There are no audible alarms. I I c c o o n n P P r r i i o o r r i i t t y y a a l l a a r r m m N N a a m m e e...
Page 38
A A c c c c e e s s s s o o r r i i e e s s a a n n d d p p a a r r t t s s These parts are currently available for purchase. Call Stryker Customer Service at 1-800-327-0770 for availability and pricing.
Page 39
P P r r e e v v e e n n t t i i v v e e m m a a i i n n t t e e n n a a n n c c e e At a minimum, check all items listed during annual preventive maintenance for all Stryker Medical products. You may need to perform preventive maintenance checks more often based on your level of product use.
Page 40
For United States only. Confirm availability for your configuration or region. Call Stryker Customer Service: 1-800-327- 0770. Stryker’s preferred wipes (2060-000-001 6'' x 10'' or 2060-000-002 9'' x 12'') include the following active ingredients: • n-Alkyl (60% C14, 30% C16, 5% C12, 5% C18) dimethyl benzyl ammonium chloride - 0.154% •...
Page 41
C C l l e e a a n n i i n n g g W W A A R R N N I I N N G G • Always check the CPR connector before use, if visibly soiled, replace. Direct skin contact with soiled material may increase the risk of infection.
Page 42
D D i i s s i i n n f f e e c c t t i i n n g g W W A A R R N N I I N N G G • Always check the CPR connector before use, if visibly soiled, replace. Direct skin contact with soiled material may increase the risk of infection.
Page 43
T T o o p p c c o o v v e e r r r r e e p p l l a a c c e e m m e e n n t t T T o o o o l l s s r r e e q q u u i i r r e e d d : : •...
Page 44
E E M M C C i i n n f f o o r r m m a a t t i i o o n n W W A A R R N N I I N N G G •...
G G u u i i d d a a n n c c e e a a n n d d M M a a n n u u f f a a c c t t u u r r e e r r ’ ’ s s d d e e c c l l a a r r a a t t i i o o n n - - E E l l e e c c t t r r o o m m a a g g n n e e t t i i c c I I m m m m u u n n i i t t y y Power frequency (50/60 Hz) 30 A/m 30 A/m...
I I s s o o A A i i r r s s y y s s t t e e m m i i s s s s u u i i t t e e d d f f o o r r u u s s e e i i n n t t h h e e e e l l e e c c t t r r o o m m a a g g n n e e t t i i c c e e n n v v i i r r o o n n m m e e n n t t s s p p e e c c i i f f i i e e d d b b e e l l o o w w . . T T h h e e c c u u s s t t o o m m e e r r o o r r t t h h e e u u s s e e r r o o f f I I s s o o A A i i r r s s y y s s t t e e m m s s h h o o u u l l d d m m a a k k e e s s u u r r e e t t h h a a t t i i t t i i s s u u s s e e d d i i n n s s u u c c h h a a n n e e n n v v i i r r o o n n m m e e n n t t .
Page 47
G G u u i i d d a a n n c c e e a a n n d d M M a a n n u u f f a a c c t t u u r r e e r r ’ ’ s s d d e e c c l l a a r r a a t t i i o o n n - - E E l l e e c c t t r r o o m m a a g g n n e e t t i i c c E E m m i i s s s s i i o o n n s s I I s s o o A A i i r r is intended for use in an electromagnetic environment specified below.
Page 49
S S y y s s t t è è m m e e I I s s o o A A i i r r ® ® M M a a n n u u e e l l d d ' ' u u t t i i l l i i s s a a t t i i o o n n 2941 2941-009-001 Rev AA.0 2021/07...
Page 51
S S y y m m b b o o l l e e s s Consulter le manuel ou la notice d'utilisation Consulter la notice d’utilisation Avertissement général Mise en garde Réanimation cardiopulmonaire (RCP) Indique que ce produit ne contient pas de substances ou d'éléments toxiques et dangereux au- dessus de la concentration maximale des six substances visées par la législation RoHS de la Chine.
Page 52
Solides : Protégé contre le contact avec les doigts et les objets supérieurs à 12 mm I I P P 2 2 1 1 Liquides : Protégé contre les chutes verticales de gouttes d'eau Pour les brevets américains, consulter www.stryker.com/patents Maintenir au sec Limite d’empilement en nombre Ce côté-ci vers le haut...
Page 53
T T a a b b l l e e d d e e s s m m a a t t i i è è r r e e s s Définition de « Avertissement », « Mise en garde » et « Remarque » ..............2 Résumé...
Page 54
D D é é f f i i n n i i t t i i o o n n d d e e « « A A v v e e r r t t i i s s s s e e m m e e n n t t » » , , « « M M i i s s e e e e n n g g a a r r d d e e » » e e t t « « R R e e m m a a r r q q u u e e » » Les termes A A V V E E R R T T I I S S S S E E M M E E N N T T , M M I I S S E E E E N N G G A A R R D D E E et R R E E M M A A R R Q Q U U E E ont une signification particulière et doivent faire l’objet d’une lecture attentive.
Page 55
• Toujours penser à utiliser les barrières. Il est conseillé d’utiliser la surface de support avec les barrières pour améliorer la sécurité d’utilisation. Un risque accru de chutes peut exister en l’absence de barrières. Une blessure grave ou le décès peut résulter de l’utilisation (possibilité...
Page 56
• Toujours faire attention aux dispositifs ou équipements posés sur la surface de support. Un endommagement de la surface peut se produire à cause du poids ou des bords tranchants de l’équipement ou de la chaleur générée par celui- • Ne pas placer de surmatelas ou d’accessoires à l’intérieur de la housse pour éviter le risque de réduction de la performance de redistribution de la pression.
Page 57
D D e e s s c c r r i i p p t t i i o o n n d d u u p p r r o o d d u u i i t t Le système I I s s o o A A i i r r ® modèle 2941 de Stryker se compose d’une surface de support et d’une pompe. La surface de support est une surface de support pneumatique qui se compose de cellules d’air et de poches réparties sur la surface pour...
Page 58
D D u u r r é é e e d d e e v v i i e e u u t t i i l l e e p p r r é é v v u u e e La surface de support I I s s o o A A i i r r a une durée de vie utile prévue de 3 ans dans des conditions d’utilisation normales assorties d’une maintenance périodique appropriée.
Page 59
Stryker se réserve le droit de modifier ces caractéristiques sans préavis. C C o o n n d d i i t t i i o o n n s s a a m m b b i i a a n n t t e e s s...
Page 60
Housse supérieure Connecteur RCP Poignée de transport Sangle d’arrimage Anneau en D (voir la section Mise en Emplacement de l’étiquette légale place des draps) Sangles avec anneau en D, centrales Câble AST inférieures Housse inférieure 2941-009-001 Rev AA.0...
Page 61
I I l l l l u u s s t t r r a a t t i i o o n n d d u u p p r r o o d d u u i i t t - - p p o o m m p p e e Interface utilisateur graphique Pied anti-vibration Indicateur d’état...
Pour consulter votre mode d'emploi ou votre manuel d'entretien en ligne, consulter https://techweb.stryker.com/. Avoir le numéro de série (A) du produit Stryker à disposition avant d’appeler le service clientèle ou le support technique de Stryker. Inclure le numéro de série dans toutes les communications écrites.
Page 65
I I n n s s t t a a l l l l a a t t i i o o n n I I n n s s t t a a l l l l a a t t i i o o n n d d e e l l a a s s u u r r f f a a c c e e d d e e s s u u p p p p o o r r t t Déballer les cartons et vérifier tous les éléments.
Page 66
F F i i g g u u r r e e 2 2 – – I I n n s s é é r r e e r r l l e e s s s s a a n n g g l l e e s s d d ’ ’ a a r r r r i i m m a a g g e e 9.
Page 67
I I n n s s t t a a l l l l a a t t i i o o n n d d e e l l a a p p o o m m p p e e Déballer les cartons et vérifier tous les éléments.
Page 68
a. Installation avec le lit ProCuity (page 17) b. Installation avec le lit InTouch (page 18) c. Installation avec le lit 3002 S3 ou le lit 3005 S3 (page 19) d. Installation avec le lit GoBed II (page 20) e. Installation avec le lit Spirit Plus ou le lit Spirit Select (page 21) 7.
Page 69
I I n n s s t t a a l l l l a a t t i i o o n n a a v v e e c c l l e e l l i i t t P P r r o o C C u u i i t t y y F F i i g g u u r r e e 6 6 –...
Page 70
I I n n s s t t a a l l l l a a t t i i o o n n a a v v e e c c l l e e l l i i t t I I n n T T o o u u c c h h F F i i g g u u r r e e 8 8 –...
Page 71
I I n n s s t t a a l l l l a a t t i i o o n n a a v v e e c c l l e e l l i i t t 3 3 0 0 0 0 2 2 S S 3 3 o o u u l l e e l l i i t t 3 3 0 0 0 0 5 5 S S 3 3 F F i i g g u u r r e e 1 1 0 0 –...
Page 72
I I n n s s t t a a l l l l a a t t i i o o n n a a v v e e c c l l e e l l i i t t G G o o B B e e d d I I I I F F i i g g u u r r e e 1 1 2 2 –...
Page 73
I I n n s s t t a a l l l l a a t t i i o o n n a a v v e e c c l l e e l l i i t t S S p p i i r r i i t t P P l l u u s s o o u u l l e e l l i i t t S S p p i i r r i i t t S S e e l l e e c c t t F F i i g g u u r r e e 1 1 4 4 –...
Page 74
R R a a c c c c o o r r d d e e m m e e n n t t d d u u c c o o n n n n e e c c t t e e u u r r R R C C P P e e t t d d u u c c â â b b l l e e A A S S T T Pour raccorder le connecteur RCP et le câble AST : 1.
Page 75
F F o o n n c c t t i i o o n n n n e e m m e e n n t t A A V V E E R R T T I I S S S S E E M M E E N N T T •...
Page 76
Pour transférer un patient entre deux surfaces de support : C C o o n n d d i i t t i i o o n n p p r r é é a a l l a a b b l l e e : : Respecter le protocole hospitalier relatif au transfert de patient entre deux surfaces de support. 1.
Page 77
F F i i g g u u r r e e 2 2 3 3 – – M M a a x x I I n n f f l l a a t t e e ( ( G G o o n n f f l l a a g g e e m m a a x x i i m m u u m m ) ) R R e e m m a a r r q q u u e e - - L’icône M M a a x x I I n n f f l l a a t t e e (Gonflage maximum) clignote jusqu’à...
Page 78
00:15:00 F F i i g g u u r r e e 2 2 6 6 – – A A n n n n u u l l e e r r M M a a x x I I n n f f l l a a t t e e ( ( G G o o n n f f l l a a g g e e m m a a x x i i m m u u m m ) ) R R e e m m a a r r q q u u e e - - Aucune autre fonction n’est disponible jusqu’à...
Page 79
F F i i g g u u r r e e 2 2 9 9 – – M M o o d d e e s s t t a a t t i i q q u u e e a a c c t t i i v v é é R R e e m m a a r r q q u u e e - - Les flèches de réglage s’allument en vert après avoir appuyé...
Page 80
F F i i g g u u r r e e 3 3 1 1 – – M M o o d d e e A A L L P P d d é é s s a a c c t t i i v v é é R R e e m m a a r r q q u u e e - - La surface de support alterne entre la zone A et la zone B à...
Page 81
D D é é m m a a r r r r a a g g e e o o u u a a r r r r ê ê t t d d u u m m o o d d e e A A S S T T Le mode AST est activé...
Page 82
F F i i g g u u r r e e 3 3 7 7 – – F F P P A A a a c c t t i i v v é é e e V V e e r r r r o o u u i i l l l l a a g g e e o o u u d d é é v v e e r r r r o o u u i i l l l l a a g g e e d d e e l l ’ ’ é é c c r r a a n n Il est impossible de changer de mode lorsque l’écran est verrouillé.
Page 83
S S t t o o c c k k a a g g e e d d e e l l a a s s u u r r f f a a c c e e d d e e s s u u p p p p o o r r t t M M I I S S E E E E N N G G A A R R D D E E - - Toujours stocker le produit dans les conditions environnementales spécifiées.
Page 84
D D é é p p a a n n n n a a g g e e P P r r o o b b l l è è m m e e C C a a u u s s e e A A c c t t i i o o n n r r e e c c o o m m m m a a n n d d é...
Page 85
P P r r o o b b l l è è m m e e C C a a u u s s e e A A c c t t i i o o n n r r e e c c o o m m m m a a n n d d é é e e É...
Page 86
A A l l a a r r m m e e s s d d u u p p r r o o d d u u i i t t Les alarmes de ce produit sont uniquement visuelles. Il n’y a pas d’alarme sonore. I I c c ô...
Page 87
A A c c c c e e s s s s o o i i r r e e s s e e t t p p i i è è c c e e s s Ces pièces sont actuellement disponibles à la vente. Appeler le service clientèle de Stryker au +1-800-327-0770 pour connaître la disponibilité...
Page 88
E E n n t t r r e e t t i i e e n n p p r r é é v v e e n n t t i i f f Au minimum, vérifier tous les éléments mentionnés pendant l’entretien préventif annuel pour tous les produits Stryker Medical.
Page 89
Destiné aux États-Unis uniquement. Confirmer la disponibilité en fonction de la configuration du produit ou du pays. Contacter le service clientèle de Stryker : +1-800-327-0770. Les lingettes recommandées par Stryker (2060-000-001 6” x 10” (15,2 cm x 25,4 cm) ou 2060-000-002 9” x 12” (22,9 cm x 30,5 cm)) contiennent les principes actifs suivants : •...
Page 90
N N e e t t t t o o y y a a g g e e A A V V E E R R T T I I S S S S E E M M E E N N T T •...
Page 91
D D é é s s i i n n f f e e c c t t i i o o n n A A V V E E R R T T I I S S S S E E M M E E N N T T •...
Page 92
R R e e m m p p l l a a c c e e m m e e n n t t d d e e l l a a h h o o u u s s s s e e s s u u p p é é r r i i e e u u r r e e O O u u t t i i l l s s r r e e q q u u i i s s : : •...
I I n n f f o o r r m m a a t t i i o o n n s s d d e e C C E E M M A A V V E E R R T T I I S S S S E E M M E E N N T T •...
Page 94
O O r r i i e e n n t t a a t t i i o o n n e e t t d d é é c c l l a a r r a a t t i i o o n n d d u u f f a a b b r r i i c c a a n n t t – – I I m m m m u u n n i i t t é é é é l l e e c c t t r r o o m m a a g g n n é é t t i i q q u u e e Baisses de tension, 0 % U pendant 0,5 cycle à...
L L e e s s y y s s t t è è m m e e I I s s o o A A i i r r e e s s t t a a d d a a p p t t é é p p o o u u r r u u n n e e u u t t i i l l i i s s a a t t i i o o n n d d a a n n s s l l ’ ’ e e n n v v i i r r o o n n n n e e m m e e n n t t é é l l e e c c t t r r o o m m a a g g n n é é t t i i q q u u e e s s p p é é c c i i f f i i é é c c i i - - d d e e s s s s o o u u s s . . L L ’...
Page 96
O O r r i i e e n n t t a a t t i i o o n n e e t t d d é é c c l l a a r r a a t t i i o o n n d d u u f f a a b b r r i i c c a a n n t t – – É É m m i i s s s s i i o o n n s s é é l l e e c c t t r r o o m m a a g g n n é é t t i i q q u u e e s s L’I I s s o o A A i i r r est destiné...
Page 98
Stryker Medical 3800 E. Centre Avenue Portage, MI 49002 2941-009-001 Rev AA.0 2021/07 WCR: AA.4...