Operating manual
6 — Height:
• Height of lift (in millimetres) of the insert during the welding process.
• Too much height will increase arc blowback (see §4.5). Too little height exposes the
Too little height exposes the weld to short circuiting because of deformation of the stud tip during welding.
7— Force :
• Adjustable from 0 to 4. Applies to the force with which the insert is pushed into the weld pool
(forging).
• At 0 the immersion force is zero, at 4 it is maximum. If the weld does not comply with the ratio between the diameter and the maxi-
mum thickness of the sheet (see §4.2). It may be necessary to reduce this force to avoid
piercing through.
Pressing the Menu/Validate button
Press the return button
7.4.3. CONFIGURATION MENU
Press the G+ and G- keys to move the cursor on the left (Pre-gas, Post-gas, Language Reset machine, Information).
When the pre-gas, post-gas or language items are highlighted, press the D+ and D- keys to change their respective values.
Test
Range of settings
Pregas
NoGas then 0,2 to 3 seconds
Post-gas
NoGas or 0.2 to 3 seconds
Language
FR, GB, DE, NL, ES, IT, RU
Push the return button
to return to the Main Menu.
7.4.3.1. COUNTERS
When «Counters» is selected, the display shows:
- the log counter: number of welds made correctly since the product was put into operation. This counter is reset to zero when the
product is restarted.
- the total counter: number of welds made correctly by the unit since it left the factory.
- The activation/deactivation of the warning message regarding checking the ground rods (see §6.1). Valid in the case of pull ring
welding only, and for the ArcPull 200-350 gun only. Press G+ and G- to switch ON or OFF.
Translation of the original
instructions
will confirm the weld settings and return the unit to the manual weld screen.
to ignore the settings and return to the Main Menu.
Configuration
> Pregas
Postgas
Language
Counts
Product reset
Info
Comment
To weld with gas shielding, it is recommended to have a
pre-gas of at least 0.4 seconds.
When welding is done with gas shielding, it is recom-
mended to have a post-gas of at least 0.4 seconds.
Daily Count
Total Count
Rods check
> 0.4s
0.4s
EN
Counts
xxxx
xxxxxxx
> ON
ARCPULL 200
41