Operating manual
5.4. USING THE STEEL AND ALU STUD BOX 200 & 350 (REF 059443 & 059436)
Note : Prepare the ground rods as explained in §5.1.
Note 2 : Prepare the stud holder as explained in §5.2.
Remove the knurled nut (No. 2 - Fig. 2)
from the gun shaft and screw in the stud
holder.
Screw the gas protection nozzle lightly
onto the stud holder, insert the stud hol-
der until it stops and then tighten the gas
protection nozzle.
Assemble the gas shield and the foot-
plate according to the required tool
configuration:
(pay attention to the positioning of the
holes).
Attach the assembly to the gun rods.
Loosen the gun knob (no. 3 in figure 2).
Adjust the shoe + cap assembly so that
the end of the weld attachment is protru-
ding slightly (0.5-2 mm) and tighten the
knob of the gun.
Translation of the original
instructions
Configuration 1
0.5 to 2
mm
ARCPULL 200
Configuration 2
0.5 to 2
mm
35