56 | ACS 652 | ACS 652 settings
11.7
UV dye
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
ENTER CODE 0000
2222
and confirm with E.
3. Enter code
4. Select "UV DYE" with o u and confirm with E.
5. Activate or deactivate with o u and confirm with E.
"
UV dye filling is activated or deactivated.
i
Return with <Stop>.
!
Only use dyes that have been approved by Bosch.
Non-approved dyes can lead to problems due to
chemical incompatibility with the internal compo-
nents in ACS 652. In the event that non-approved
dyes are used, no warranty claims shall be appli-
cable.
11.8
Enter serial number
i
The serial number is located on the rating plate on
the back of the housing of ACS 652.
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
ENTER CODE 0000
2222
and confirm with E.
3. Enter code
4. Select "SERIAL NUMBER"" with o u and confirm
with E.
5. Enter serial number with <A – Z>,<0 – 9> and con-
firm with E.
"
Serial number is set.
i
Return with <Stop>.
|
S P00 D00 158
2019-02-21
11.9
11.9.1
i
is displayed.
ACS 652 can store the R134a consumption data dur-
ing all charging and extraction processes.
!
This function can only be activated or deactivated by
customer service.
11.9.2
i
The data storage of ACS 652 may contain more data
than can be printed on one paper roll (printer).
1. Press <MENU>.
2. Select "REPORT MANAGEMENT" with o u and
confirm with E.
3. Select "PRINT REPORT" with o u and confirm with
E.
 The number of saved protocols is displayed.
4. Print all protocols with E .
"
All protocols are printed.
i
Return with <Stop>.
i
is displayed.
We recommend that stored reports are exported,
printed and then deleted at least once a week.
11.9.3
!
All data on the PS2 stick is deleted!
1. Press <MENU>.
2. Select "REPORT MANAGEMENT" with o u and
confirm with E.
3. Select EXPORT DATA with o u and confirm with E.
4. Insert PS2 stick.
"
All protocols are saved on the PS2 stick.
i
The software A/C Data Manager (optional acces-
sory) can be used to view and manage the data on
a PC.
Service data report
Activate/deactivate consumption R134a re-
port
Printing data
Exporting data
Robert Bosch GmbH