11. ACS 652 settings
11.1
Factory setting
Menu
LANGUAGE
DATE/TIME
UNIT OF MEASURE
HOSES LENGTH
CONTRAST
GARAGE ADDRESS
FLUSHING
OIL SCALE
UV DYE
SERIAL NUMBER
EXPERT MODE
11.2
Set unit
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
ENTER CODE 0000
2222
and confirm with E.
3. Enter code
4. Select "UNIT OF MEASURE" with o u and confirm
with E.
 kg/lb are displayed.
5. Select unit with o u and confirm with E.
"
Unit is set.
i
Return with <Stop>.
11.3
Set length of service hoses
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
ENTER CODE 0000
2222
and confirm with E.
3. Enter code
4. Select "HOSES LENGTH" with o u and confirm with E.
 Available lengths (2.5 m, 5 m, 7.5 m and 10 m)
are displayed.
5. Select hose length with o u and confirm with E.
"
Hose length is set.
i
Return with <Stop>.
Robert Bosch GmbH
Factory setting
English
CET
kg/m
2,5 m
medium contrast
empty, no data entered
deactivated
activated
activated
Serial number has already been
entered (compare with name
plate)
deactivated
is displayed.
is displayed.
ACS 652 settings | ACS 652 | 55
11.4
Contrast
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
ENTER CODE 0000
2222
and confirm with E.
3. Enter code
4. Select "CONTRAST" with o u and confirm with E.
 A numeric index is displayed on the screen indi-
cating the contrast level.
5. Adjust contrast with o u and confirm with E.
"
Contrast is set.
i
Return with <Stop>.
11.5
Scales for fresh and used oil
i
In the event of faults the "oil charge" and "oil drain"
scales can be switched off to avoid blocking of the
unit.
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
ENTER CODE 0000
2222
and confirm with E.
3. Enter code
4. Select "OIL SCALE" with o u and confirm with E.
5. Activate or deactivate with o u and confirm with E.
"
Oil scales are activated or deactivated.
i
Return with <Stop>.
11.6
Flush (optional)
i
Optionally, special accessories for the cleaning
of vehicle A/C components can be connected for
ACS 652. If these special accessories are used, this
function must be activated in the selection menu.
en
is displayed.
is displayed.
|