3.
Safety regulations
!
Always carefully read and observe all the safety regu-
lations before using the Bosch product.
¶
Wear safety goggles.
¶
Wear safety gloves.
3.1
Handling refrigerant R134a
Avoid all skin contact with the refrigerant.
The low boiling point of the refrigerant (ap-
prox. -30 °C) can lead to frostbites. Should
it nevertheless come into contact with the
skin, remove any moistened clothing imme-
diately and rinse the affected skin with copi-
ous amounts of water.
R
R134a is colorless, has a weak intrinsic odor and is
heavier than air. It displaces oxygen and may flow
into repair pits. Should refrigerant escape (malfunc-
tion), always ensure adequate ventilation and air
extraction (especially in pits). Exit the workshop.
Never inhale refrigerant and oil vapors. The
vapors can irritate the eyes, nose and respi-
ratory system. If liquid refrigerant comes
into contact with the eyes, rinse them thor-
oughly with water for 15 minutes. Then ob-
tain medical help even if no pain is felt.
R
Before connecting the ACS 652 to a vehicle air con-
ditioning system or an external refrigerant cylinder,
make sure the quick-release couplings are not leak-
ing.
R
Only ever use external refrigerant cylinders provided
with safety valves and certified in line with the ap-
plicable standards.
R
Before switching off the ACS 652, make sure all fill-
ing and drainage operations have been completed.
This prevents refrigerant escaping into the environ-
ment.
Do not use compressed air with R134a.
Some air mixtures with R134a are highly
flammable. Such mixtures are a potential
hazard and may lead to fire or explosions
and thus cause damage or injury.
R
Refrigerant extracted from a vehicle air conditioning
system may be contaminated with moisture, lubri-
cant, dirt and traces of other gases.
|
S P00 D00 158
2019-02-21
R
R134a is not to be used in areas in which there is a
danger of explosion. Fire, naked flames and smok-
ing are prohibited. Welding and soldering are not
permitted.
R
High temperatures and UV radiation may chemically
separate the R134a. The resultant products cause
coughing and nausea.
R
R134a is not to be mixed with other refrigerants.
The mixing of refrigerants can damage the vehicle
air conditioning system.
3.2
Handling UV dye
Never inhale UV dye. The vapors can irritate the
eyes, nose and respiratory system. If UV dye
comes into contact with the eyes, rinse them
thoroughly with water for 15 minutes. Then
obtain medical help even if no pain is felt.
R
Avoid all skin contact with the UV dye. Should it nev-
ertheless come into contact with the skin, remove
any moistened clothing immediately and rinse the
affected skin with copious amounts of water.
R
Never swallow UV dye. If swallowed inadvertently,
never attempt to induce vomiting. Drink copious
amounts of water and obtain medical help.
3.3
Working on the vehicle
If high-voltage components or high-voltage
wires are inexpertly handled, there is a risk of
fatal injury from high voltages and the possi-
ble transmission of current through the body.
R
De-energization is only to be performed by a quali-
fied electrician, a qualified electrician for specific
tasks (hybrid), or a power systems engineer.
R
Work on vehicles with high-voltage components is
only ever to be performed in a safe, de-energized
condition by persons with the minimum qualification
"Trained to perform electrical work".
R
Even after deactivating the high-voltage vehicle
electrical system, the high-voltage battery may still
be live.
R
The operating condition cannot be established from
any running noise, as the electric machine is silent
when stationary.
R
In gear positions "P" and "N" the engine or electric
motor may start spontaneously depending on the
charge of the high-voltage battery.
R
Never open or damage high-voltage batteries.
R
On accident vehicles, never touch high-voltage com-
ponents or exposed high-voltage wires before deac-
tivating the high-voltage vehicle electrical system
Robert Bosch GmbH