Cut-out installation 400 x 400

For optimum sealing we recommend the use of the sealing
frame that is available as accessory (part no. 40091-19000).
For installation with a sealing frame, please refer to the instal-
lation instructions provided with the sealing frame.
When installing the device in vehicles with an existing roof
hatch, the cut-out must measure 400 x 400 mm.
Remove existing roof hatch (make cut-out bigger if necessary).
Remove sealant residue and unevenness.
Fill in screw holes with body sealant.
Fig. 19
For the other installation steps, please refer to "Preparation
for power cable connection".

Installation with new cut-out

For vehicles without an existing cut-out:
required cut-out 350 x 380 mm.
Place template on installation location on vehicle, mark cutout
(350 x 380 mm) and cut it out.
Mark the 4 holes (10 mm) for bracket attachment and drill
holes in roof.
Fig. 20
All manuals and user guides at all-guides.com

Preparation for power cable connection

Provide leadthrough for mains cable to connection point, e.g.
in the false ceiling.
Fig. 21
Move device to roof in a horizontal position and insert into
cut-out. The arrow should point in the direction of travel.
Fig. 22
it on.
Push device forwards in cut-out as far as it will go.
Remove protective film from device.
Route mains cable to connection point (lengthen cable with
provided Wago clamps if necessary).
available as an accessory must now be connected. The instal-
lation instructions are provided with the 12 V adapter.
Fig. 23
Do not apply any additional sealing materials between
the air conditioning system and the roof.
If the device was turned around or moved out of its hori-
zontal installation position, wait 2 hours before switching
If the lighting of the air distributor is also going to be
optionally operated using 12 V, the 12 V adapter that is