correct
correct
Fig. 5:
Additional recommendations on installation
installing a weld-end fitting
Follow the previously described general installation
recommendations.
english
36
installing a fitting with flange
→
Make sure the seals are in good condition.
→
Place seals adapted to the process in the groove
of each end.
→
Tighten the flange to fix the fitting to the pipe.
Make sure the seal remains in the groove while
tightening the flange.
8.
commiSSioninG
Warning
danger due to non-conforming commissioning.
Non conforming commissioning may lead to injuries and
damage the fitting and its surroundings.
•
Before commissioning, make sure that the staff in
charge have read and fully understood the contents of
the manual.
•
In particular, observe the safety recommendations and
intended use.
•
The installation must only be commissioned by suitably
trained staff.
english
38
incorrect
incorrect
note
the seal on the fitting with weld-end connections
may be damaged during welding.
→
Before welding the weld-ends, unscrew the 4 tight-
ening screws.
→
Remove the sensor holder from the fitting.
→
Remove the seal.
→
Weld the weld-ends.
→
After welding, correctly replace the seal in the
groove.
→
Replace the sensor holder on the fitting.
→
Tighten the 4 screws in an alternating pattern, applying
a nominal tightening torque of 1,5 Nm.
installing a fitting with clamp
connections
→
Make sure the seals are in good condition.
→
Place seals adapted to the process in the
grooves of the Clamp fitting.
→
Fix the Clamp fitting to the pipe by means of a clamp
collar.
9.
mAinTenAnce
Safety instructions
danger
risk of injury due to high pressure in the installation.
•
Stop the circulation of fluid and release the pressure
before loosening the process connections.
risk of injury due to high fluid temperatures.
•
Use safety gloves to handle the fitting.
•
Stop the circulation of fluid and bleed the pipe before
loosening the process connections.
•
Keep all easily flammable fluid and material away from
the fitting.
risk of injury due to the nature of the fluid.
•
Respect the prevailing regulations on accident preven-
tion and safety relating to the use of aggressive fluids.
Warning
risk of injury due to non-conforming maintenance.
•
Maintenance must only be carried out by qualified and
skilled staff with the appropriate tools.
•
Ensure that the restart of the installation is controlled
after any interventions.
english
37
37
english
39
39