DN
P
A
Standard
[mm]
[mm]
[mm]
40
39,6
120
DIN 8063
106
DIN 16962
106
ISO 10931
50
45,7
130
DIN 8063
110
DIN 16962
110
ISO 10931
L
english
24
Material
Connection type and standards
Weld-ends
•
acc. to SMS 3008
•
acc. to BS 4825 / ASME BPE
•
acc. to DIN 11850 series 2
•
acc. to EN ISO 1127 / ISO 4200
external thread
•
acc. to SMS 1145
•
acc. to G
internal thread
•
G, Rc, NPT
clamp
•
acc. to SMS 3017 / ISO 2852
•
acc. to BS 4825 / ASME BPE
•
acc. to DIN 32676
•
acc. to ISO (for piping acc. to
EN ISO 1127 / ISO 4200)
english
26
L
D
H
[mm]
[mm]
[mm]
30,0
50
31,5
23,0
23,0
37,0
63
39,5
27,0
27,0
A
K factor
DN6
-
-
-
-
-
440
-
-
-
-
-
K factors (in imp/l)
The K factors have all been determined under the following
terms of reference: fluid = water, water and room tempera-
tures of 20°C, minimum upstream and downstream dis-
tances respected, appropriate pipe dimensions.
If the S030 fitting is combined with an electronic
device which does not automatically convert the
k factors, make the conversion using one of the
following formulae:
K factor in imp/gallon US = K factor in imp/l x
3,785 to obtain flow rate in gallon US / time unit
K factor in imp/gallon UK = K factor in imp/l x
4,546 to obtain flow rate in gallon UK / time unit
K factor (imp/l)
DN8 DN15 DN20 DN25 DN32 DN40 DN50 DN65
-
-
-
66.85 -
-
-
105.7 66.85 49.03 31.08 19.92 11.36
278 105.7 105.7 66.85 49.03 31.08 19.92 -
105.7 66.48 49.03 31.82 19.84 11.36 -
-
-
-
-
66.85 -
278 105.7 66.48 49.03 31.82 19.84 11.36 -
105.7 66.48 49.03 31.82 19.84 11.36 -
-
-
-
-
66.85 -
-
-
105.7 66.85 -
278 105.7 105.7 66.85 -
105.7 66.48 49.03 31.82 19.84 11.36 -
-
english
25
25
31.08 19.92 11.36
31.08 19.92 -
31.08 19.92 11.36
31.08 19.92 11.36
31.08 19.92 -
english
27