Electric wire rope winch THETA
En g lish
Instructions for securing the ends of wire ropes
Hanging the rope and securing the rope: The end of a newly fitted wire rope
has to be configured in such a way that its end is permanently secured and the
structure of the rope cannot work loose.
The end connection of the wire rope has to be regularly examined (fractured
wires – corrosion – cracks in the sleeve – loose clamping screws etc.).
As end connections you are only allowed to use the following:
Aluminium press-fit connections according to
Splice connections according to
Rope clamps
Rope clamps
DIN EN 13411-7
(DIN 15315) or similar to DIN EN
13411-6 (DIN 43148)
The free end of the rope has to be secured against being pulled through.
Connection type C is PROHIBITED for hoists and load suspension equipment.
 Wire rope clamps acc. to DIN EN 13411-5
be used as rope end connections in hoisting operations.
The winch should be given a thorough examination by a competent person at least once a year.
Always ensure the maintenance intervals are adhered to.
Only use original accessories and spare parts; otherwise safe function is not guaranteed.
Functional description
The wire rope winch THETA is a drum winch with spur gear.
The load is held in every position by an electromagnetic ventilating disk brake.
The winch is provided with electric remote-control switching with mounted-in push-buttons up/down,
emergency stop push-button/switch and main switch.
2

Mounting Instructions

Mounting:
Attention
Mounted structures for max. design forces (according to EN 13001)
Pay careful attention that the mounting surface is flat and true.
Only fix the winch by means of good quality screws.
Tighten the screws evenly.
Secure the screws.
Pay attention to unhindered rope coiling!
Mechanical fixing:
screws
material grade
number of screws
tightening torque [Nm]
technische Änderungen vorbehalten
DIN EN 13411-3 (DIN 3093)
DIN EN 13411-2 (DIN 3089)
Rope connection
secured
with additional rope clamp
acc. to DIN EN 13411-5
(DIN 1142)
DIN 1142) are not allowed to
(
M10
min. 8.8
4
40
design changes under reserve
04.01.700
Aluminium press-fit
DIN EN 13411-3 (DIN 3093)
(uncovered)
Only permitted in
elevator building
changements techniques sous réserve
Splice connections
DIN EN 13411-2
(DIN 3089) (uncovered)
18