Menu elements
Actions
8.5

Display modes

Display test
max
min
2
Fig. 27: Display test
8.5.1 Display status page
8.5.2 Display menu mode
Installation and operating instructions SIE-DIE-PBE
• Menu status page: Standard view on the display
12.3
• "One level down": A menu element that can be used to jump to
4.1.0.0
a lower menu level (e.g. <4.1.0.0> to <4.1.1.0>
• "Information": A menu element that shows information about the
4.4.3.0
device status or settings that cannot be changed
• "Selection/setting": A menu element that provides access to
±
2.0.0.0
a changeable setting (element with menu number <X.X.X.0>)
"One level up": A menu element that can be used to jump to a higher
menu level (e.g. <4.1.0.0> to <4.1.1.0>
Menu error page: In the event of an error, the current error number
E000
is displayed instead of the status page.
• Turn red button: Turn the red button or increase or decrease settings
or menu numbers.
• Press red button: Press the red button to activate a menu element or
confirm a change.
• Navigate: Perform the steps that follow to navigate in the menu to
the displayed menu number.
• Wait time: The remaining time (in seconds) is displayed on the value
display until the next state is reached automatically or manual input
can be made.
ON
• Set DIP switch to the OFF position: Set the DIP switch number "X"
under the housing cover to the OFF position.
X
ON
• Set DIP switch to the ON position: Set the DIP switch number "X"
under the housing cover to the OFF position.
X
As soon as the power supply of the electronic module has been estab-
lished, a 2-second display test is carried out, during which all charac-
ters on the display are shown (Fig. 27). Afterwards the status page is
displayed.
After interruption of the power supply, the module carries out various
shut-off functions. The display will be shown for the duration of this
process.
DANGER! Danger of death!
There can be electrical charges present in the display even if is
switched off.
• Observe general safety instructions!
The standard view on the display is the status page. The current set-
12.3
point is displayed in the number segments. Other settings are dis-
played using symbols.
NOTE
For dual pump operation, the operating mode is also shown as sym-
bols on the status page ("Parallel operation" or "Main/reserve"). The
display of the slave pump shows 'SL'.
The electronic module functions can be called via the menu structure.
The menu contains sub-menus on several levels.
The current menu level can be changed using "One level up" or "One
level down" menu items, for example, to change from menu
<4.1.0.0.> to <4.1.1.0>.
English
77