salmson SIE Installation Et Mise En Service page 108

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
English
11.3.3 Error type C
1
2
3
4
5
6
7
8
Fig. 48: Error type C, diagram
6.0.0.0
E000
6.0.0.0
- - -
3/6
6.0.0.0
300
5/6
6.0.0.0
6/6
Fig. 49: Acknowledge error type C
102
• To change to menu mode, press the red button.
• Press the red button again.
E000
12.3
S
E000
12.3
S
• Wait until the remaining time is up.
0
12.3
S
• Press the red button again.
Error type C (Fig. 48):
Program
Contents
step/query
1
• Error code is displayed
• Motor Off
• Red LED On
2
Error criterion fulfilled?
3
> 5 minutes?
4
• Error meter is incremented
5
Error meter > 5?
6
• SSM is activated
7
Error acknowledged?
8
End; auto control resumes
Yes
No
If type C errors occur, proceed as follows to acknowledge (Fig. 49):
Menu number <6.0.0.0> flashes on the display.
Menu number <6.0.0.0> appears steady on the display.
On the value display, '- - -' appears.
On the units display, the current incidence (x) as well as the maximum
incidence of the error (y) are displayed in the format 'x/y' .
After 300 seconds, the current incidence will be counted up by one.
NOTE:
The error will be acknowledged automatically if the cause of the error
is eliminated.
If the current incidence (x) is the same as the maximum incidence of
the error (y), this can be manually acknowledged.
The error is acknowledged, and the status page is displayed.
Pompes Salmson 04/2012