Bosch Rexroth AG
WARNING!
CAUTION!
NOTE!
9

Maintenance and Repairs

9.1

Maintenance

Electric shock due to contact with live parts, unexpected belt section start-up
Severe injuries or death.
Switch off the power supply before performing any maintenance or repair work.
Switch off the compressed air supply before performing any maintenance or
repair work.
Take suitable measures to prevent inadvertent restoration.
Hot electric motor surfaces during operation
Possible burns if the hot surface (up to 70°C) is touched.
Provide appropriate safety devices to seal off the motors.
Let the system cool off for at least 30 min. before performing any maintenance or
repair work.
3
Fig. 7
9.1.1 Bearings
All bearings are provided with lifelong lubrication and are maintenance-free under
normal conditions.
Bearing malfunctions
Moistening of the bearings with grease-dissolving substances, e.g. for cleaning
purposes, will lead to bearing malfunctions. There is a danger of damage to property.
Keep grease-dissolving or aggressive cleaning agents away from the bearings!
Only clean the belt section with a slightly damp cloth.