3 842 540 837 (2010.02)
TS 2pv
15 Technical Data
• For dimensions, see the TS 2pv transfer system sales catalog, 3 842 540 432
• Section load: Max. 120 kg, dependent on the speed and the number of tracks.
23, diagram of the permissible load and operating time.
– Each track: max. 0.08 kg/cm of surface length, max. 60 kg, dependent on the
speed.
– Example:
CSS/B-2, v
= 36 m/min, m
N
CSS/BM-5, v
= 21 m/min, m
N
• Conditionally suitable for reversible operation.
• Suitable for use in ESD sensitive areas. For more information, please contact your
Rexroth representative.
• Noise emissions: < 70 dB (A)
15.1
Ambient conditions
• The transfer systems have been designed for stationary use in a location that is
protected from the elements
• Operating temperature +5°C to +40°C
• Storage
temperature
• Relative humidity
• Air pressure
• Load values are reduced by 15% when the system is set up in a location that is
> 1400 m.
• Avoid molds, fungi, rodents, and other vermin.
• Do not install or operate near industrial systems with chemical emissions.
• Do not install or operate near sandy or dusty sources.
• Do not install or operate in areas that are regularly jarred by high forces caused by
e.g. presses or heavy machinery.
• Resistant to many common media used in production such as water, mineral
oil, grease, and detergents. Contact your Rexroth representative if you have any
doubts about resistance to specifi c chemicals, e.g. test oil, doped oils, aggressive
detergents, solvents, or brake fl uid.
• Avoid long-term contact with acidic or basic reacting materials.
15.2
Pneumatics
• Oiled or non-oiled, fi ltered, dry compressed air
• Operating pressure: 4 to 6 bar
= 45 kg
Perm.load
= 112 kg
Perm.load
–5°C to +60°C with 20% reduced load
–25°C to +70°C
5% to 85%
> 84 kPa, appropriate height < 1400 m above sea level.