Code
Possible settings
No.
Name
Lenze
C0002*
Transferring
s
parameter sets
with the keypad
uSEr
(Continua
tion)
C0002*
Transferring
s
parameter sets
with the keypad
uSEr
(Continua
tion)
C0002*
Saving your own
s
basic setting
uSEr
(Continua
tion)
EDK82EV903 DE/EN/FR 5.1
Important codes for quick commissioning
Selection
Keypad ð controller
70
with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen
10
with all other function modules
Keypad ð PAR1 (+ FPAR1)
71
with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
11
with all other function modules
Keypad ð PAR2 (+ FPAR1)
72
with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
12
with all other function modules
Keypad ð PAR3 (+ FPAR1)
73
with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
13
with all other function modules
Keypad ð PAR4 (+ FPAR1)
74
with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
14
with all other function modules
Controller ð keypad
80
with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
20
with all other function modules
Keypad ð function module
40
only with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
Function module ð keypad
50
only with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
PAR1 ð own basic setting
9
l
Commissioning
IMPORTANT
By means of the keypad you can
transfer the parameter sets to other
controllers.
During the transmission the access to
the parameters via other channels is
inhibited!
Overwrite all available parameter sets
(PAR1 ... PAR4, if required FPAR1) with
the corresponding data of the keypad
Overwrite selected parameter set and,
if required FPAR1, with the
corresponding data of the keypad
Copy all available parameter sets
(PAR1 ... PAR4, if required FPAR1) into
the keypad
Only overwrite the module−specific
parameter set FPAR1 with the data of
the keypad
Only copy the module−specific
parameter set FPAR1 into the keypad
For the parameters of the controller
you can save an own basic setting
(e.g. the delivery status of your
machine):
1. Ensure that parameter set 1 is
active
2. Inhibit controller
3. Set C0003 = 3, confirm with v
4. Set C0002 = 9, confirm with v,
the own basic setting is saved
5. Set C0003 = 1, confirm with v
6. Enable the controller
7
177