Wiring of controller inhibit (CINH) when two function modules are operated

6.1.3
Wiring of controller inhibit (CINH) when two function modules are operated
)
Note!
ƒ
ƒ
Internal DC voltage supply
FIF I
E82ZAFx
+20V
GND3
X3
20
28
39 7
0
External voltage supply
FIF I
E82ZAFx
+20V
GND2
X3
20
28
39 7
0
166
Both terminals X3/28 of the interface FIF I and FIF II are evaluated internally
via an AND−operation.
The following illustrations show possible methods of wiring. Considering
the AND−operation of both terminals X3/28, wiring can be adapted to your
application.
FIF II
E82ZAFSC010
+5V
+20V
GND1
GND1
X3
62
9
7 20 28 E1 E2 E3 E4 39 A1 59
0
For function modules with terminals X3/7 and X3/39: Install a wire jumper between X3/7
and X3/39
PES
HF shield termination by large−surface connection to PE
Wiring of the other terminals: ^ Mounting instructions of the function modules
FIF II
E82ZAFSC010
+5V
+20V
GND1
GND1
X3
62
9
7 20 28 E1 E2
...
0
For function modules with terminals X3/7 and X3/39: Install a wire jumper between X3/7
and X3/39
PES
HF shield termination by large−surface connection to PE
Wiring of the other terminals: ^ Mounting instructions of the function modules
l
GND2
X3
GND2
X3
E3 E4 39 A1 59
+
24 V ext.
(
+12 V -0 % ...
+30 V +0 %, max. 120 mA)
0.5...0.6 Nm
4.4...5.3 lb-in
PES
PES
8200vec262
0.5...0.6 Nm
4.4...5.3 lb-in
PES
PES
8200vec263
EDK82EV903 DE/EN/FR 5.1