14.1.1
Pump key definition
1. Electrical version
•
E60
•
•
•
•
•
•
configurable operation modes:
Internal operation
Setting of metering quantity/metering frequency in:
•
•
•
External operation
•
•
•
Inputs:
•
•
•
•
•
Outputs:
•
low-level monitoring of bundle holder / fault (reserve and empty report)
•
Fault report
•
•
PLUS
E60
•
•
•
417101799_EMP_IV_E60.docx
E60
Main switch for switching On/Off the pump
mechanical stroke adjustment
backlit graphical display, 4 control keys
individual stroke control (each stroke is executed completely)
metering control via stroke signal output (computed)
or via external metering monitoring system
collection of operating and consumption data (computed)
calibration function
Strokes/min.
Percentage
Litres/hr (or gallons/hr)
Pulse operation (control via pulses)
-
Pulse multiplication (1 incoming pulse = n metering strokes)
-
Pulse division (n incoming pulses = 1 metering stroke)
Standard signal operation (control via external standard signal 0/4 - 20 mA or 20 - 0/4 mA)
Batch operation (a preset quantity is metered after being triggered by external enable pulse)
low-level monitoring of bundle holder (reserve and empty report)
pulse
standard signal
enabling signal (metering lock)
metering monitoring
stroke signal
similar to E60, but with the addition of a dongle plate for connecting of oval gear meter OGM
PLUS
(expansion unit for the capture of operating data)
display of the currently measured metering quantity and automatic readjustment of pump output
(only in conjunction with an external through flow monitoring system, e.g. oval gear meter
PLUS
OGM
)
automatic calibration function via oval gear meter
consumption data monitoring via oval gear meter