Connector assignments of Slot I (3-terminal)
7.2.4.1
input for low-level advance warning and empty report
Fig. 7.18
7.2.4.1.1 Installing the suction pipe with low-level advance warning and empty report
Slot I must always be assigned, either through the mounted strapping plug (protective cap
NOTE
with corresponding symbol; see Chapter 5.2.1, Fig.5.3, Pos. 11) or through connection to
the empty report device.
Fig. 7.19
417101799_EMP_IV_E60.docx
PIN
terminal
assignment
configu-
of connector
ration X1
plug
1
1
2
3
3
4
(plug assignments: see also chapter
Specifications")
1
+
4
(PIN assignment of connector plug) =
Input low-level advance warning
Switch contact low-level advanced warning open
low-level advanced warning active (invertible circuit
logic, see chapter
10.3.8), empty report symbol on
display flashes, pump is not locked.
PIN
Assignment
1
Relay input low-level advance warning
GND ( ┴ )
4
3
+
4
(PIN assignment of connector plug) =
Input empty report
Switch contact empty report
empty report active (invertible circuit logic, see chapter
10.3.8), empty report symbol on display appears, pump
is locked.
PIN
Assignment
3
Relay input empty report
GND ( ┴ )
4
- 79 -
Conductor
coloring
Assignment
(cable
connection)
brown
Input low-level advance
warning
blue
Input empty report input
black
GND ( ┴ )
14.5.1
"Technical
:
open:
Rev. 9-06.11