Drawing 14
5.
CLEANING AND MAINTENANCE.
To ensure the correct operation of your boiler, the following Cleaning and maintenance operations are
necessary at the indicated frequency. The boiler must always be cold.
5.1.
Heat Exchanger.
Pull the drawers of the rake-this shall be done while the glass door closed in order to reach the ash inside the
boiler. This shall be done every day when the boiler is cold. See drawing 16 (Hidrocopper).
The Super Insert model has an automated cleaning system which frees us from this task.
q
Drawers of the rake.
If the boiler is an insert Hidrocopper model, you must open the front door as shown in drawing 17 and
repeatedly activate the drawers of the rake (
to the ash falls into the boiler. This operation must be performed everyday with the cold boiler.
q
Front door.
w
Drawers of the rake.
In Hidrocopper models, Hidrocopper cerámica and Hidrocopper mini, the user can change the place of the
drawers of the rake as appropriate. To perform this operation, you need to open the side doors. Then, you
must remove the handle (
DAILY CLEANING WHEN THE BOILER IS COLD.
). This work should be done with the glass door closed in order
w
e
) of the drawers. Unscrew the handles (
42
Drawing 15
Drawing 16
Drawing 17
w
) of the drawers of the rake and