New floor.
Rehabilitations and alterations.
*NT: Number of premises which can have driven devices leading to the courtyard.
COMPLIANCE WITH THESE NORMS ARE OUT OF ECOFOREST'S CONTROL; ECOFOREST DOES NOT BEAR THE
RESPONSIBILITY FOR ANY RESULTING DAMAGE.
WE RECOMMEND THAT A CONFIRMED SPECIALIST SETS UP YOUR PELLETS BOILER.
4.23.
Check the space between the boiler, the fuel, and any flammable material.
4.24.
Do not install the boiler in a sleeping room.
4.25.
The power cable provided by ECOFOREST is 1.5m long; you might need a longer one. Always use a cable with
ground plug.
Security distances should be respected when the boiler is surrounded by flammable items.
A
Lateral side of the boiler.
B
Shelf.
C
Ground protection.
The gas outlet pipe can be installed over the wall with an elbow of 45°, 90° or with a flexible stainless steel
pipe, forming a "T" with 1.5m vertically, see drawing 5:
4.26.
Choose the place where you are going to put the boiler, paying attention to location section. Installation will
be very simple and should not affect the structure, water system or electricity installation of your home.
4.27.
Set a non flammable protection between the ground and the boiler.
4.28.
Consider security distances between the boiler and the walls, see below table:
Houses, between party wall of sets
of semidetached houses in new
floor.
Residential buildings.
Any kind of building or house.
LOCATION OF THE BOILERS.
FREE SPACES.
MINIMUM DISTANCES WITH FLAMMABLE MATERIAL.
420 mm
400 mm
150 mm
GAS OUTLET THROUGH WALL.
S= 1.0·x NT, minimum of 6.00 m
The ventilition by coutyards is
forbidden.
S= 0.5·x NT, minimum of 4.00 m
36
2
.
2
.
Drawing 3