q
Screws for keyboard setting.
e
Keyboard's connection band and C.P.U.
r
Back side of keyboard.
t
Thermostat connection.
y
Power connection ~230/240V - 50Hz.
u
Thermostat.
r
Keyboard.
t
Thermostat connection.
y
Power connection ~230/240V - 50Hz.
u
Thermostat.
Optionally available:
•
A wireless thermostat prepared with all the connections (see quartering).
•
An external connection adapter where a room thermostat from any manufacturer can be connected. (See
quartering). It should not take more than 10 meters of wire and it must be shielded.
•
An optocoupler port (On/Off External) the external contact for the ON or OFF requires an activation through
the l "Menu 3 – Technical service" in section 3-4 ON ext. this operation must be performed by qualified
personnel (see quartering) CAUTION!, THOSE CONTACTS MUST NOT BEAR TENSION, THAT IS, IT MUST BE
AN OPEN OR CLOSED CONTACT, IN NO CASE ~230/240V - 50Hz AS THIS MAY DAMAGE THE C.P.U.
IF YOU HAVE ANY DOUBT ABOUT THE CONNECTION, THE INSTALLATION PRACTICABILITY OR THE
USE OF SUCH DEVICES, CONTACT YOUR DISTRIBUTOR WHO WILL INFORM YOU.
A BAD USE OR SETTING OF THESE DEVICES MAY CAUSE A MALFUNCTION OR EARLY
DEGRADATION OF THE BOILER.
If the boiler that you have is an Hidrocopper insert, you must fix the safety thermostat to the panels of the
insert model. These panels have a hole, through which you must insert the thermostat (
and fix it to the socket with a nut (
model, showing the final result in the drawing 15.
ASSEMBLING OF THE SAFETY THERMOSTAT IN INSERT MODELS
) and finally you screw the stopper (q). The boiler used in drawings is an EcoII
w
41
Drawing 12
Drawing 13
) according to drawing 14,
e