4.2 Function Description
Getting Started – First time use.
For first-time use, follow the steps below:
1. Make sure that your physician or care provider has initialized and configured the appropriate
treatment values into the unit.
2. Make sure that your package contains a face or nasal mask with headgear. If not, your
physician or care provider can recommend the type of mask and headgear you must obtain
3. Attach tubing and mask (see Setup section).
4. Attach power cord to the unit and an electrical outlet (see Setup section). Unit will
power-on automatically.
5. Use the "MENU" button to set the Current Time, Ramp Up Time, and Ramp Starting
Pressure, (see "MENU" Button Section for description of these options).
Note that these values may have been already set by your physician or care provider.
6. Press the "START/STANDBY" button – Airflow to the mask will begin.
7. You can now place the Headgear and Mask over your head and face and begin treatment
4.3 Menu Button - Option Descriptions
The following items describe the options presented to you after you press the "MENU" button on
the control panel.
(1) Ramp Time (only CPAP mode)
Ramp time function allows the user to fall asleep with a lower, more comfortable pressure
and helps them gradually become accustomed to increasing treatment pressure. The
second selection of pressing "MENU" is [Ramp XX MIN]. When the "MENU" setting is in
[Ramp XX MIN] mode, press "UP" or "DOWN" button to set the preferred ramp time and
press "MENU" for confirmation. There are 10 adjustable levels, 0, 5, 10, 15, 20, 25, 30, 35,
40 and 45 minutes.
(2) Ramp Starting Pressure (only CPAP mode)
Press "MENU" button to select [Ramp P XX.X] menu, press "UP" or "DOWN" button to
set the preferred ramp starting pressure and press "MENU" for confirmation. The ramp
starting pressure can be changed from 3 cmH
example, if your therapy pressure is 10 cmH
can select is 9 cmH
O.
2
(3) Therapy Pressure (only CPAP mode)
Press "MENU" button to select [P
setting displayed in cmH
O unit. Therapy pressure is adjustable only by the provider, a
2
respiratory therapist or physician.
NOTE: The therapy pressure is to only be prescribed by a physician.
O to "Therapy Pressure – 1" cmH
2
O, the maximum ramp starting pressure you
2
O] menu, you can view the current pressure
XX.XcmH
2
8
Italiano
Appare un messaggio di Errore / Attenzione sul display
Tipo di messaggio
Errore:
Non è possibile
eseguire le
funzioni
primarie
Attenzione:
NOTA: Quando appare il messaggio di errore, contattare il medico o il fornitore per scaricare i dati
della memoria e resettare il misuratore.
O. For
2
Definizione
Errore dovuto a impostazioni del sistema
anormali
Errore per guasto al generatore del flusso.
Errore per impostazione anormale del
temporizzatore o guasto al temporizzatore.
Errore per guasto al sensore del flusso.
Memoria del sistema insufficiente
La memoria del sistema è quasi piena
Errore di comunicazione del modulo della
scheda SD
Togliere la scheda SD durante
l'elaborazione dei dati
La scheda SD è piena.
Inconsistent ID no. of device with SD card
Wrong firmware version of SD card module
SD card is damaged
153
Messaggio sul display
Error 001
Error 002
Error 003
Error 004
Warn 001
Warn 002
Warn 003
Warn 004
Warn 005
Warn 006
Warn 007
Warn 008