Hygienic Weighing Module Novego®
Minebea Intec
Note:
The following tools are required:
-
Screwdriver SW13 for M8 screws (19).
-
Screwdriver SW30 for adapter plate screws (5).
-
Screwdriver SW30 for height adjustment using adjustment sleeve (16).
-
2.5 mm Allen key for securing the height adjustment.
1.
Fit lange (15) to the vessel foot (13). Make sure to use the correct tightening torques
(see Chapter 5.2).
2. Insert the O-ring (14) into the groove of the adapter plate (5).
3. Screw the height adjustment (18) into the adapter plate (5). Make sure to use the
correct tightening torques (see Chapter 5.2).
4. Loosen the 2 pin screws (17).
5. Adjust the height using the adjustment sleeve (16).
The arrow on the height adjustment limits the adjustment range (80
160 mm).
6. Secure the adjustment using 2 pin screws (17).
5 Installation
EN-30