Hygienic Weighing Module Novego®
Designation
Nominal ambient
temp. range
Service temperature
range
Storage temperature
range
Permissible eccentri-
city
Vibration resistance
Barometric pressure
inluence
Nominal delection
NTEP: min. scale interval of the load cells v
Type
Class III
D1/D1E
Multiple
C3/C3E
Class III L
D1/D1E
Multiple
C3/C3E
Minebea Intec
Description
to hold the speciied performance
permissible for continuous operation wi-
thout damage
without electrical and mechanical stress
Permissible distance from the measuring
axis
Resistance against oscillations
(IEC 60068-2-6 Fc)
inluence of barometric pressure on output
for E
125 kg:
max
for E
≥250 kg:
max
elastic deformation under maximum capa-
city
for E
≤500 kg:
max
for E
≥1 t:
max
Deinitions acc. to VDI/VDE 2637
The technical data given are intended solely as a product description and should not be
interpreted as guaranteed properties in the legal sense.
min
Divisions
125 kg
n
max
5000
8.9
5000
...
10000
7.8
10000
...
Abbr. D1
B
T
B
Tu
B
Ti
S
Ex
PK
Smin
PK
Smin
s
nom
s
nom
250 kg
500 kg
...
...
17.8
35.7
...
...
7.8
11.9
4 Speciications
C3
-10 to +40
-40 to +95
-40 to +95
±2.5
20 g, 100 h,
10 to 150 Hz
<9
...
...
<17
max. 0.1
max. 0.1
...
max. 0.2
1 t
2 t
...
...
71.4
142
...
...
23.8
47.6
Unit
°C
°C
°C
mm
g/kPa
g/kPa
mm
mm
Unit
g
g
g
g
EN-16