Hygienic Weighing Module Novego®
4.2
General information
Restoring force
Load cell material
Material of pendulum
base
Protection classes
Protection type
Ambient temperature in
the Ex area
Cable diameter
Cable length
Cable gauge
Cable bend radius
Cable sheath material
Cable sheath color
4.3
Possible marking of the load cell for the Ex area
Zone
0 and 1
20 and 21
2
22
Minebea Intec
Displacement of the load cell onto the pendulum base generates a restoring force
that increases with the force applied to the load cell. If the load cell is displaced by 2.5
mm, the pendulum base reaches its stopper.
Stainless steel 1.4418 acc. to DIN EN 10088-3
Stainless steel 1.4301 acc. to DIN EN 10088-3 (corresponds to AISI 304, B.S. 304S15)
and 1.4418 acc. to DIN EN 10088-3
in compliance with EN 60529
IP68/IP69:
Dust-proof and leak-tight against water, with harmful efects when immersed, (1.5 m
water depth, 10,000 h) and water jets (high pressure and temperature).
Explosion:
Suitable for explosion subgroup IIC and IIIC.
Intrinsic safety for PR 6261/..E
see additional information "safety instructions for Ex load cells"
only with approval RU С-DE.МЮ62.B.05836: -52
+55 °C
5 mm
5 m
2
4×0.35 mm
≥25 mm (ixed installation)
≥75 mm (lexible installation)
Thermoplastic elastomer (TPE)
Gray (standard version)
Blue (Ex version)
Marking
II 1G Ex ia IIC T6 Ga
Ex ia IIC T6 Ga
0Ex ia IIC T6
II 1D Ex ta IIIC T160 °C Da
Ex ta IIIC T160 °C Da
Ex ta IIIC T160 °C X
II 3G Ex nA IIC T6 Gc
2Ex nA IIC T6 X
II 3D Ex tc IIIC T85 °C Dc
Ex tc IIIC T85 °C X
Certiicate no.
BVS 16 ATEX E 005
IECEx BVS 16.0005
RU С-DE.МЮ62.B.05836*
TÜV 03 ATEX 2301X
IECEx TUN 17.0025X
RU С-DE.МЮ62.B.05836*
MIN16ATEX001X
RU С-DE.МЮ62.B.05836*
MIN16ATEX001X
RU С-DE.МЮ62.B.05836*
* Certiication body: Prommash Test LLC
(Accrediting code МЮ62)
4 Speciications
for
only PR 6261/..E
all PR 6261 without /..E
all PR 6261 without /..E
all PR 6261 without /..E
EN-8