Tightening Torques; Assembly; Safety Instructions - Minebea Intec Novego Manuel D'installation

Masquer les pouces Voir aussi pour Novego:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Hygienic Weighing Module Novego®
5.2

Tightening torques

5.3

Assembly

5.3.1

Safety instructions

Minebea Intec
lack of sensitivity to transversal forces will be negatively afected under these
circumstances.
Installation with adapter plate
For information on creating a mounting option for an M16 connection with the weighing
object, see Chapter 5.3.2.1.
Installation without adapter plate
Use the drilling template to generate the load cell drilling pattern (see Chapter 4.4)
according to the weighing system arrangement.
Installation with height adjustment
Create the drilling pattern for an M8 connection with the weighing object using the
drilling template for each vessel base according to the weighing system arrangement (see
Chapter 4.7).
The corresponding tightening torques are given in the following table.
Mounting parts
Adapter plate/load cell
Pendulum base/support
plate
Pendulum base/bottom
Weighing object/set
screw/cap nut
Weighing object/height-
adjustment lange
Adapter plate/height-ad-
justment threaded bolt
Pendulum pin
* Recommendation for the was-
hers of M8 mounting screws:
WARNING
The vessel may turn over during mounting.
Securing the vessel against tipping is imperative.
Use an appropriate lifting jack.
Thread
Washer
M6-A2-70
M8-A2-70
*
M8-A2-70
or
M10-A2-50
M16
M8-A2-70
M16
M12
DIN 7349 (d = 21, h = 4) or DIN 9021 or ISO 7093-2 (d =
24, h = 2)
5 Installation
Tightening torque
3.5 Nm
16 Nm
16 Nm
or
14 Nm
59 Nm
16 Nm
59 Nm
30 Nm
EN-22

Publicité

Table des Matières
loading

Table des Matières